Normal/Emergency Screen Display - Toshiba TOSVERT VF-AS3 Instruction Manual

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

3. 2

Normal/emergency screen display

This section explains the screen display of the operation panel.
When operation such as parameter setting is not performed, the top screen of [Standard mode] is
displayed. During run, output frequency, etc. are displayed, and the status of alarm and trip is displayed
when an error occurs.
3. 2. 1
Normal display
When the inverter is stopped, the screen
on the right is displayed.
Status area
at the left end is stopped
• As status, "STOP" is displayed.
• The frequency command value
"20.0 Hz" is displayed
(<F723: Status area display of
operation panel> = "1: Frequency
command value")
• The run command is selected from operation panel, Extension panel (
Main area
• The output frequency "0.0 Hz" is displayed (<F710: Standard mode display> = "0: Output
frequency")
During run of the motor, the screen shown on the right is
displayed.
Status area
at the left end rotates
• As status, "RUN" is displayed
• The frequency command value "20.0 Hz" is displayed
(<F723: Status area display of operation panel> = "1:
Frequency command value")
• The run command is selected from operation panel,
Extension panel (
Main area
• The output frequency "20.0Hz" is displayed (<F710: Standard mode display> = "0: Output
frequency")
STOP
Standard Mode
Screen
Copy
).
3-17
20.0Hz
17:12
0.0
Hz
Setting
Monitor
RUN
Standard Mode
20.0
Screen
Copy
3. [Basic operation] Operation panel and screen display
E6582062
Status area
3
Mode name area
Main area
Function area
).
9
10
20.0Hz
17:18
Hz
Setting
Monitor