2. 2. 3
The parts to be removed are as follows.
• Front cover in the middle of the front surface (metal)
• Wiring cover on the lower side of the front surface
(metal)
• Top cover on the top surface (metal)
2
Each cover can be removed separately.
■ Front cover
1
Remove four screws of the front cover.
Store the removed screws so as not to be lost.
2
Remove the front cover from the unit.
9
3
Mount the front cover in the reverse procedure.
■ Wiring cover
1
Remove four screws of the wiring cover.
Store the removed screws so as not to be lost.
2
Remove the wiring cover from the unit.
3
Mount the wiring cover in the reverse procedure.
2. Installation and wiring
With frame size A5
VFAS3-2220P to 2370P, VFAS3-
4450PC to 4750PC
Top cover
Front cover
Wiring cover
Front cover
Wiring cover
2-14
E6582062
Screw
Screw
Front cover
Wiring cover