6. 30. 15 Brake answer waiting time setting
<F630: Brake answer wait time>
■ Function
This parameter can set the waiting time for the brake answer (reply) from the system. Input brake
answer to the input terminal with "130: Brake answerback" is assigned.
After the operation start, when there is no answer after elapse of the setting time, the inverter trips.
The trip display is "E-11".
■ Parameter setting
Title
Parameter name
F630
Brake answer wait time
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
Reference
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• This function is used with "brake function".
About "brake function", refer to "E6582104".
F630 : Brake answer wait time
Min: 0.0
X1000
Adjustment range
0.0: Disabled
0.1 - 10.0
6-141
E6582062
STOP
0.0Hz
14:00
0.0
S
Max: 10.0
X100
X10
X1
Unit
Default setting
s
0.0