Display Of Embedded Ethernet Setting Screen - Toshiba TOSVERT VF-AS3 Instruction Manual

Embedded ethernet function
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

1.5. Display of Embedded Ethernet setting screen

Inverter IP address can be set easily by Embedded Ethernet setting screen from guidance function of LCD
panel. In addition, current settings can be checked in the monitor display by scrolling the screen.
Access Embedded Ethernet setting screen of the
guidance function with the following operation.
[ESC] key => Select "3. Guidance function"
=> [OK] key => Select "3.1 Embedded Ethernet"
=> [OK] key
The Embedded Ethernet setting screen
allows you to set IP address setting mode,
IP address, subnet mask, default gateway and
device name.
In addition, you can check the currently settings
in the monitor display by scrolling the screen.
Here is an example when the IP address
192. 168. 0. 1 is obtained by DHCP server.
Standard Mode screen
STOP
Standard Mode
Screen
Copy
Embedded Ethernet setting screen
STOP
Embedded Ethernet
Device Name
IP setting
IP address
Mask
Gateway
Top
STOP
Embedded Ethernet
Mask
Gateway
IP address monitor
Mask monitor
Gateway monitor
Top
5
E6582125
0.0Hz
21:19
0.0
Hz
Setting
Monitor
0.0Hz
21:19
DHCP
0. 0. 0. 0
0. 0. 0. 0
0. 0. 0. 0
Return
Monitor
0.0Hz
21:19
0. 0. 0. 0
0. 0. 0. 0
192. 168. 0. 1
255. 255. 255. 0
192. 168. 0. 200
Return
Monitor

Hide quick links: