 Assign "184: Number of external equipment starting alarm" to the unused output terminal. For
details, refer to [7. 2. 2].
[Monitor mode]
 Set "103: External equipment counter" to <F711: Monitor mode 1 display> through <F718: Monitor
mode 8 display>. For details, refer to [8. 1. 1].
■ Signal output of the number of occurrence of the specified trip
You can confirm occurrence of the specified trip in [Monitor mode]. You can set up to three specified
trips.
Set the monitor numbers shown in the following table to <F711: Monitor mode 1 display> to <F718:
Monitor mode 8 display>. For details, refer to [8. 1. 1].
 "113: Number of specified trip 1"
 "114: Number of specified trip 2"
 "115: Number of specified trip 3"
4
4
Memo
6
9
Reference
6. [Advanced] How to use parameters
• The number of starting, the number of forward run, and the number of reverse starting up to the
present time can be confirmed in [Monitor mode]. You can reset the monitor value to 0 with the
setting of "12: Clear number of starting" in <tyP: Default setting>. For details, refer to [5. 2. 9].
• You can reset the monitor value of "external equipment counter" to 0 with the setting of "14:
Clear number of external equipment starting" in <tyP: Default setting>. For details, refer to [5. 2.
9].
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details on operation by external signals -> Refer to [Chapter 7].
6-152