Toshiba TOSVERT VF-AS3 Instruction Manual page 563

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

Function number
Symbol
Positive
Negative
logic
logic
102
103
CPSW
104
105
FCHG
106
107
FMTB
108
109
CMTB
110
111
PWE
112
113
STSW
114
115
EXCUT
116
117
PI1SW
118
119
SS5
120
121
FSTP1
122
123
FSTP2
124
125
PREX
126
127
BRK
130
131
BRKA
134
135
TVS
136
137
RSC
138
139
PMPSW
140
141
SLOWF
142
143
STOPF
144
145
SLOWR
146
147
STOPR
148
149
SLOFR
150
151
HSC
Function
Commercial powr run
ON: Commercial power run, OFF: Inverter run
switching
ON: <F207: Frequency command select 2> enabled
FMOd/F207 priority
switching
OFF: <FMOd: Frequency command select 1> enabled
ON: Frequency command of Terminal [II] enabled
Terminal II priority
OFF: <FMOd: Frequency command select 1> enabled
ON: Run command of terminal enabled
Terminal run priority
OFF: <CMOd: Run command select> enabled
ON: Parameter writing unlocked
Parameter writing
OFF: <F700: Parameter reading & writing access lockout>
unlocked
setting
Speed control/Torque
ON: Torque control, OFF: Speed control
control switching
External equipment
ON: Count the signals (Monitor number "103" can monitor
counter
the number of ON signal)
PID 1, 2 switching
ON: PID2, OFF: PID1
Preset speed switching 5
Selection of 31-speed SS1 to SS5 (5 bits)
ON: Dynamic quick deceleration
OFF: Canceled
Quick deceleration 1
*Operation is resumed when dynamic quick deceleration is
canceled
ON: Quick deceleration
Quick deceleration 2
OFF: Canceled
*Operation is resumed when quick deceleration is canceled
Preliminary excitation
ON: Preliminary excitation
Brake
ON: Brake closed
ON: Comparison signal with output terminal function "68:
Brake answerback
During brake release" ("E-11" trip when mismatching)
Traverse operation
ON: Traverse operation permission
Rescue operation
ON: Rescure operation (Low voltage operation)
Pump control switching
ON: Pump switching during pump control
ON: Forward run toward the setting value of <F383: Hit and
Fwd slowdown
stop frequency>
Fwd stop
ON: Stop (Forward run only)
ON: Reverse run toward the setting value of <F383: Hit and
Rev slowdown
stop frequency>
Rev stop
ON: Stop (Reverse run only)
Fwd/Rev slowdown
ON: Stop (Forward/Reverse run)
Hit and stop clear
ON: Hit and stop cleared
11-61
Action
(When <F200: Frequency command priority select> =
"0")
E6582062
Reference
[6. 20]
[7. 2. 1]
[5. 4. 1]
[7. 2. 1]
1
[7. 2. 1]
[5. 2. 1]
[7. 2. 1]
3
[6. 34. 1]
[7. 2. 1]
[7. 2. 1]
[6. 30. 21]
[7. 2. 1]
[7. 2. 1]
[5. 3. 7]
[7. 2. 1]
[7. 2. 1]
9
10
[6. 30. 15]
[7. 2. 1]
11
[7. 2. 1]
11. Table of parameters