6. 10 Jog run

<F262: Panel jog run>
<F260: Jog frequency>
<F261: Jog stop select>
■ Function
Jog run represents inching the motor.
4
When you input a jog run signal, the inverter immediately outputs a jog run frequency regardless of
the set acceleration time.
4
You can start/stop jog run even on the operation panel.
6
■ Parameter setting
Title
F262
F260
F261
9
■ Setting example
Assign "18: jog run" to the unused input terminal.
While that input terminal is turned ON, the inverter can perform jog run.
To use only the panel jog run, you should not assign it to the input terminal.
Example) When it is assigned to the terminal [RES]: <F113: Terminal RES function 1> = "18"
The inverter outputs a low-speed detection signal but does not output an output frequency
attainment signal during jog run. Also, PID control is disabled.
<Example of jog run>
Terminal [RES] (JOG): ON + terminal [F]: Forward jog run when the terminal is turned ON
Terminal [RES] (JOG): ON + terminal [R]: Reverse jog run when the terminal is turned ON
(Frequency command + terminal [F]: Forward run when the terminal is turned ON, terminal [R]:
Reverse run when the terminal is turned ON)
6. [Advanced] How to use parameters
Parameter name
Panel jog run
Jog frequency
Jog stop select
F262 : Panel jog operation
0: Disabled
1: Enabled
Adjustment range
0: Disabled
1: Enabled
F240 - 20.0
0: Deceleration stop
1: Coast stop
2: DC braking stop
6-44
E6582062
STOP
0.0Hz
13:11
Unit
Default setting
0
Hz
5.0
0