6. 24. 4
Selecting stall operation during regeneration
<F453: Stall operation during regen>
■ Function
This function is one of the functions to prevent the lifting gear from being displaced at stop. If current
stall prevention gets active during regeneration of controlled stop, there may be a mismatch at stop.
Set to inhibit only the stall prevention of current.
■ Parameter setting
Title
Parameter name
F453
Stall operation during
regen
■ Selecting a setting value
To inhibit the stall prevention of current during regeneration of controlled stop, set <F453: Stall
operation during regen> to "1".
• How to operate the operation panel -> Refer to [3. 1. 1].
Reference
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
F453 : Stall operation during regen
0: 0: Enabled
1: 1: Disabled
Adjustment range
0: Enabled
1: Disabled
6-103
E6582062
STOP
0.0Hz
13:46
Default setting
0