13. Trip information and measures
Failure
Trip name
code
0012
EEPROM
Fault occurred during internal data writing. Turn off the power and then turn it on
fault 1
0013
EEPROM
1) While setting <tyP: Default setting>, the
fault 2
power was turned OFF or momentary
power failure occurred.
2) Fault occurred during internal data
writing.
0014
EEPROM
Fault occurred during internal data
fault 3
reading.
0022
Grounding
1) Grounding fault occurred in the output
fault *
wiring or the motor.
2) Fault can occur depends on motor, in
case of rapid acceleration/deceleration.
0008
Input phase
1) Input side phase has failed.
loss *
0009
Output phase
1) Output side phase has failed.
loss *
2) Output current is quite small (less than
8%) to motor rated current.
0015
RAM fault
Control RAM fault.
0016
ROM fault
Control ROM fault.
0017
CPU1 fault A
Control CPU fault.
0018
Communication
RS485 communication timed out.
time-out
(RS485)
0019
Gate array
Fault in the gate array.
fault
001A
Current
Fault in the output current detector.
detector fault
001B
Communication
Communication option timed out.
time-out
(option)
001C
Panel
While running with a run command from
disconnection
the operation panel and extension panel,
during run
the cable connecting the inverter and
panel are disconnected.
*Enable/Disable can be selected for trip with a parameter.
Detection factor
again.
If the fault occurs again, contact your
Toshiba distributor.
1) Set <tyP> again.
2) Turn off the power and then turn it on
Turn off the power and then turn it on
again.
If the fault occurs again, contact your
Toshiba distributor.
1) Check grounding fault in the wiring on
2) Increase the acceleration/deceleration
1) Check phase failure in the wiring on the
1) Check phase failure in the wiring on the
2) Set <F605> to 0
Fault in internal inverter.
Contact your Toshiba distributor.
Fault in internal inverter.
Contact your Toshiba distributor.
Fault in internal inverter.
Contact your Toshiba distributor.
Check the communication equipment and
wiring on RS485 communication.
Fault in internal inverter.
Contact your Toshiba distributor.
Fault in internal inverter.
Contact your Toshiba distributor.
Check the communication equipment and
wiring on communication option.
Check the connection on the inverter and
panel.
13-4
E6582062
Measures
If the fault occurs again, contact your
Toshiba distributor.
again.
If the fault occurs again, contact your
Toshiba distributor.
the output side and the motor.
time. <ACC/dEC acceleration/
deceleration time 1>
input side.
output side.