Status Monitor Under Normal Conditions - Toshiba TOSVERT VF-nC3E Instruction Manual

Industrial inverter (for 3-phase induction motors)
Table of Contents

Advertisement

8.2
Status monitor mode
8.2.1
In this mode, you can monitor the operation status of the inverter.
To display the operation status during normal operation:
Press the MODE key twice.
Setting procedure (eg. operation at 40Hz)
Item displayed
Operation
frequency *
Parameter setting
mode
Direction of
rotation
Operation
Note 1
frequency
command *
Note 2
Output current *
Note 3
Input voltage *
8
Output voltage *
Inverter
load factor *
Operation
frequency *
(Continued overleaf)
* Monitor items can be selected by setting parameters  to , ().
Refer to page H-8 for notes.

Status monitor under normal conditions

Panel
LED
operated
display


MODE

MODE






Communic
ation No.
The operation frequency is displayed (Operation at
60Hz). (When standard monitor display selection
 is set at 0 [operation frequency])
The first basic parameter "" (history function)
is displayed.
The direction of rotation is displayed.
FE01
(: forward run, : reverse run)
The operation frequency command value (Hz/free
FE02
unit) is displayed.
( In case of = )
The inverter output current (load current) (%/A) is
FE03
displayed.
( In case of = )
The inverter input voltage (DC detection) (%/V) is
FE04
displayed.
( In case of = )
The inverter output voltage (%/V) is displayed.
FE05
( In case of = )
The inverter load factor (%) is displayed.
FE27
( In case of = )
The operation frequency (Hz/free unit) is
FD00
displayed.
( In case of = )
H-2
E6582233
Description
Note 11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents