13 Press the [OK] key.
The screen returns to the basic parameter screen.
14 Similarly, select <Sr2: Preset speed 2> and <Sr3:
Preset speed 3> and change the setting values.
In the example on the right, <Sr2: Preset speed 2>
is set to 10.0 Hz and <Sr3: Preset speed 3> to 15.0
Hz.
15 Press the [OK] key to return to the basic parameter screen.
16 Turn on the external switch.
Leave the two relays off.
17 When you turn on relay 1, the frequency command value of <Sr1> is enabled, and the motor
starts running.
In the main area of the [Standard mode] screen, the output frequency is displayed.
: Deceleration time 1
dEC
: Preset speed 0
Sr0
: Preset speed 1
Sr1
: Preset speed 2
Sr2
: Preset speed 3
Sr3
: Deceleration time 1
dEC
: Preset speed 0
Sr0
: Preset speed 1
Sr1
: Preset speed 2
Sr2
: Preset speed 3
Sr3
4-41
4. [Basic operation] Operation methods of motor
E6582062
STOP
0.0Hz
F
R
15:59
Basic parameters
10.0s
0.0Hz
20.0Hz
10.0Hz
0.0Hz
F
R
STOP
0.0Hz
15:59
Basic parameters
10.0s
0.0Hz
20.0Hz
10.0Hz
15.0Hz
3
4
9