9
Press the [OK] key.
The screen returns to the [Standard mode] screen.
10 When you press the [RUN] key, the motor starts
running.
In the main area of the [Standard mode] screen,
the output frequency is displayed.
The motor accelerates according to the setting of
<ACC: Acceleration time 1>, and its frequency
changes to the frequency command value set with
<FC: Panel run frequency> and becomes stable.
In the example on the right, it is 30.0 Hz.
The following are always displayed in the status area on the upper side of the screen regard-
less of display mode.
(From the left)
• The
icon is rotating
• Operation status "RUN"
• Frequency command (display contents vary depending on the setting of the parameter)
• Run command icon
• You can change the frequency command value by pressing the [OK] key in [Standard mode]
and displaying the setting screen of <FC: Panel
Memo
• When you change the frequency command value with the touch wheel, the output frequency
changes accordingly.
11 To stop the motor, press the [STOP] key.
The motor decelerates according to the setting of <dEC: Deceleration time 1> and stops.
4. 3. 2
[Operation example 2] Switching forward/reverse
run with [FWD/REV] key during panel run
Switch the direction of rotation of the motor during run only by the operation panel.
• Make setting so that forward run/reverse run can be input from the operation panel.
• The parameter to be set is <Fr: Panel Fwd/Rev run select>.
Easy
Easy
run
frequency> during run.
4-23
4. [Basic operation] Operation methods of motor
E6582062
STOP
0.0Hz
F
R
14:47
Standard Mode
0.0
Hz
Screen
Copy
Monitor
RUN
30.0Hz
F
R
15:30
Standard Mode
30.0
Hz
Screen
Copy
Monitor
3
4
9