■ Function
When operating without the PG feedback (<Pt: V/f Pattern> = "0" - "9"), if the rough speed exceeds
the speed limit over the setting time, this parameter announces an error and outputs a failure.
When operating with the PG feedback (<Pt: V/f Pattern> = "10" or "11"), the parameter monitors the
speed feedback value and a trip occurs when speed exceeds the speed limit over the setting time.
When output frequency > (<FH> +12 Hz) or > (<FH> + <vL>/10) at all <Pt>, a trip occurs.
The trip display is "E-13".
■ Parameter setting
Title
Parameter name
F622
Abnormal speed
detection time
F623
Abnormal speed
increase band
F624
Abnormal speed
decrease band
■ Guideline for the setting
If speed feedback (Estimated speed) > (Output frequency + <F623>) or speed feedback (Estimated
speed) < (Output frequency - <F624>), and a certain period of time set with <F622: Abnormal speed
detection time>, a trip occurs.
You can provide range for a detection level of a trip with a setting of <F623: Abnormal speed
increase band> and <F624: Abnormal speed decrease band>
During torque control, if speed feedback (Estimated speed) > (Speed upper limit + <F623>) or >
(Speed lower limit - <F624>) a certain period of time set with <F622: Abnormal speed detection
time>, "E-13" trip occurs.
Output frequency (Hz)
0
• When the setting value is 0 (zero), this function may not become activated properly while in the
Memo
stall protection mode. To maintain this function, use of setting <F451: Acc/Dec operation after
stall operation> = "1: Minimum time" is recommended. For details, refer to [6. 24. 2].
Adjustment range
0.01 - 100.0
0.00: Disabled
0.01 - 30.0
0.00: Disabled
0.01 - 30.0
Output frequency
<F623>
<F624>
Feedback value of speed sensor
"E-13" Trip
Time (s)
<F622>
6-137
E6582062
Unit
Default setting
s
0.01
Hz
0.00
Hz
0.00
6. [Advanced] How to use parameters