■ Standard replacement cycle of the other principal parts
The estimated parts replacement cycles are shown in the following figure. They are based on the
assumption that they will be used under normal use conditions (average ambient temperature of
40°C, load factor of 80% or less, 24-hour operation per day, with no corrosive gas, oil mist, dust,
metal powder, etc. present). These replacement cycles are not the lives of the parts. They are based
on the assumption that more parts will become abnormal when they are used over these cycles.
Relays
Aluminum electrolytic capacitor on
the printed circuit board
Battery CR2032
operation panel)
*1
The replacement cycles greatly vary depending on the operating environment.
*2
It is based on the case where the inverter output current is 80% of the inverter rated current.
*3
Use CR2032EC (Toshiba).
14. 2. 3
1
Remove the operation panel from the inverter. Refer to [10.
3. 8]
2
Open the slot cover at bottom (left side) of operation panel
9
3
Eject the battery by using insulated tool (to avoid short-circuit
by remaining charge)
For disposal of battery, see [16]
4
Insert new battery, at that time take care the polarity.
14
5
Close the slot cover
Then, clock setting is needed, because the clock is not kept by replacing the battery
Refer to E6582110 for setting.
14. Maintenance and inspection
Part name
Standard replacement cycle
The remaining capacity of the
*3
(used in the
battery is indicated into the LCD
screen with icons (see 3. 1. 2)
How to replace the battery
*1
-
To be determined by inspection
Replace with a new one. (To be
*2
10 years
determined by inspection)
Replace with a new one.
14-6
E6582062
Replacement method
slot cover
-
+
new battery