The regional VA pool contains VA interfaces for interfaces that do not span multiple devices,
such as Ethernet interfaces.
When you configure a VA pool, follow these guidelines:
To change the capacity of a VA pool, you must delete the previous configuration, and
reconfigure the VA pool.
Creating or removing a VA pool takes time. During the process of creating or removing a VA
pool, users can come online or go offline, but the VA pool does not take effect.
If the system fails to create a VA pool because of insufficient resources, you can view the
available resources by using the display pppoe-server va-pool command.
VA pools are memory intensive. Set their capacity depending on your network requirements.
Deleting a VA pool does not log off the users who are using VA interfaces in the VA pool.
To configure a VA pool:
Step
1.
Enter system view.
2.
Create a VA pool (centralized
devices
mode).
3.
Create a VA pool (distributed
devices
mode/centralized
devices in IRF mode).
4.
Create a VA pool (distributed
devices in IRF mode).

Clearing PPPoE sessions

To clear PPPoE sessions on the PPPoE server:
Step
1.
Enter user view.
2.
Clear PPPoE sessions.

Configuring a PPPoE client

PPPoE client configuration includes dialer interface configuration and PPPoE session configuration.
A PPPoE session can operate in one of the following modes:
Permanent mode—A PPPoE session is established immediately when the line is physically
up. This type of session remains until the physical link comes down or until the session is
disconnected.
On-demand mode—A PPPoE session is established when there is a demand for data
transmission instead of when the line is physically up. It is terminated when idled for a specific
period of time.
Command
system-view
pppoe-server
in
standalone
template-number
va-volume
pppoe-server
in
standalone
template-number
IRF
slot-number ] va-pool va-volume
pppoe-server
template-number
chassis-number slot slot-number ]
va-pool va-volume
Command
user-view
reset
interface
interface-number
virtual-template number }
virtual-template
va-pool
virtual-template
[
slot
virtual-template
[
chassis
pppoe-server
{
all
interface-type
50
Remarks
N/A
By default, no VA pool exists.
By default, no VA pool exists.