xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
Example
To start a frame loss measurement test:
DGS-3620-28PC:admin#cfm lm 00-01-02-03-04-05 mepname mep1 period 1s
pdu_priority 7
Command: cfm lm 00-01-02-03-04-05 mepname mep1 period 1sec pdu_priority 7
Success.
DGS-3620-28PC:admin#
15-33 clear cfm dm
Description
This command is used to clear the frame delay measurement information.
Format
clear cfm dm {[mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index <uint
1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]} {[results | statistics]}
Parameters
mepname - (Optional) Specifies the MEP name.
<string 32> - Enter the MEP name. This name can be up to 32 characters long.
mepid - (Optional) Specifies the MEP ID.
<int 1-8191> - (Optional) Enter the MEP ID. This value must be between 1 and 8191.
md - (Optional) Specifies the Maintenance Domain name.
<string 22> - Enter the Maintenance Domain name. This name can be up to 22 characters
long.
md_index - (Optional) Specifies the Maintenance Domain index.
<uint 1-4294967295> - Enter the Maintenance Domain index. This value must be between 1
and 4294967295.
ma - (Optional) Specifies the Maintenance Association name.
<string 22> - Enter the Maintenance Association name. This name can be up to 22
characters long.
ma_index - (Optional) Specifies the Maintenance Association index.
<uint 1-4294967295> - Enter the Maintenance Association index.
results - (Optional) Specifies to clear the stored frame delay measurement results. If none of
them is specified, both of them are cleared.
statistics - (Optional) Specifies to clear the stored the statistics of ETH-DM frames (DMM, DMR).
If none of them is specified, both of them are cleared.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To clear the frame delay measurement information.
262