6.15.3

Charging controller (dT)

Line no.
Operating line
3810
Temp diff on
Line no.
Operating line
3811
Temp diff off
Line no.
Operating line
3812
Charg temp min DHW st tank
Line no.
Operating line
3813
Temp diff on buffer
Line no.
Operating line
3814
Temp diff off buffer
Line no.
Operating line
3816
Temp diff on swi pool
Line no.
Operating line
3817
Temp diff off swi pool
Line no.
Operating line
3818
Charging temp min swi pool
Note!
When using setting - - -, the general temperature differential solar (Temp diff on
(3810) and Temp diff off (3811)) is adopted.
When charging the storage tank via the heat exchanger, the temperature differential
between collector and storage tank/swimming pool must be sufficient, and the collector
must have reached the minimum charging temperature for the storage tank/swimming
pool.
Figure 55: Charging controller – charging temperature minimum swimming pool
Meaning
On/Off
Collector pump
SdAus
Dynamic switch-off threshold
SdEin
Switch-on threshold (heating circuit/DHW)
TKol
Collector temperature
TLmin
Minimum charging temperature DHW storage tank/buffer/swimming pool
TSp
Storage tank temperature
User Manual LMS14...
6 The settings in detail
279/617
CC1U7471en
28.01.2015