External Space Heating - Siemens LMS14 User Manual

Albatros2 boiler management unit
Table of Contents

Advertisement

Para set group OEM
Para set num OEM
Room controller HCx
468/617
Building Technologies Division
Line no.
Operating line
6235
Para set group OEM
Administration number from ACS435.
Line no.
Operating line
6236
Para set num OEM
Administration number from ACS435.
6.23.29

External space heating

Line no.
HK1
HK2
HK3
6355
6356
6357
Room controller HKx allows you to switch heating circuit 1/2/3 from internal space
heating to external space heating, and vice versa.
In the case of internal space heating, heating circuit 1/2/3 is operated as the default
heating circuit as per the configuration.
In the case of external space heating, heating circuit 1/2/3 is operated as per the rest of
the configuration when a request is received from the OT BSB interface.
Only BSB object 518 TempAnfoVeRhExt is relevant to the heating circuit function.
User Manual LMS14...
6 The settings in detail
Operating line
Room controller HCx
Automatically
Internally
Externally
CC1U7471en
28.01.2015