Operator unit
791
Optimum stop control max
794
Heat up gradient
800
Reduced setp increase start
801
Reduced setp increase end
809
Continuous pump operation
No ¦ Yes
812
Frost protection flow temp
Off ¦ On
820
Overtemp prot pump circuit
Off ¦ On
830
Mixing valve boost
832
Actuator type
2-positioin ¦ 3-position
833
Switching differential 2-pos
834
Actuator running time
835
Mixing valve Xp
836
Mixing valve Tn
850
Floor curing function
Off ¦ Functional heating ¦ Curing heating ¦
Functional/curing heating ¦ Curing/functional
heating ¦ Manually
851
Floor curing setp manually
855
Floor curing setp current
856
Floor curing day current
861
Excess heat draw
Off ¦ Heating mode ¦ Always
Building Technologies Division
Operating line
ACS420
OptStopCtrl MaxTime1
Heat up gradient
StartRedRTSetpIncrHC1
EndRedRTSetpIncrHC1
Continuous PumpOp HC1
No ¦ Yes
FrostProtFlowTemp HC1
Off ¦ On
OvertempProt HC1
Off ¦ On
MixValveSetpBoost HC1
Actuator CtrlMod HC1
Two-positioin ¦ Three-position
ActuatorSwiDiff HC1
Actuator RunTime HC1
Xp heating circuit 1
Tn heating circuit 1
FloorPlastrDryUpFnct1
Off ¦ Functional heating ¦ Curing heating ¦
Functional and curing heating ¦ Curing and
functional heating ¦ Manually
FloorSetp man HC1
FlowTmpSetFloorPlast1
FloorPlastrDryUpDay 1
Overtemp drop HC1
Off ¦ Heating mode ¦ Always
User Manual LMS14...
5 Handling
ACS700/ACS790
Optimum stop control max forward
shift HC1
Heat up gradient
Start reduced room temp setpoint
increase HC1
End reduced room temp setpoint
increase HC1
Continuous pump operation HC1
No ¦ Yes
Frost protection flow temp HC1
Off ¦ On
Pump heating circuit overtemp
protection HC1
Off ¦ On
Mixing valve setpoint boost heating
circuit 1
Actuator control mode heat circuit 1
Two-positioin ¦ Three-position
Actuator switching differential heat
circuit 1
Actuator running time heat circuit 1 120
P-band (Xp) heat circuit 1
Integral action time (Tn) heat circuit
1
Flooring plaster dry up function HC1
Off ¦ Functional heating ¦ 'Belegreif'
heating ¦ Functional + 'Belegreif' heating ¦
Belegreif' + functional heating ¦ Manuell
Floor setpoint manually HC1
Flow temp setpoint flooring plaster
dry up HC1
Flooring plaster dry up day HC1
Overtemperature drop heating
circuit 1
Off ¦ Heating mode ¦ Always
0
0
360
60
0
600
/BZ 801 10
-15
-30
BZ 800
No
On
On
5
0
50
Three-position
2
0
20
30
873
32
1
100
120
10
873
Off
25
0
95
0
95
0
32
Always
CC1U7471en
Min.
min/k
°C
°C
-
-
°C
-
°C
s
°C
s
-
°C
°C
47/617