Siemens LMS14 User Manual page 380

Albatros2 boiler management unit
Table of Contents

Advertisement

Line no.
Function
5891
Relay output QX2
5892
Relay output QX3
5894
Relay output QX4
5930
Sensor input BX1
5931
Sensor input BX2
5932
Sensor input BX3
5950
Function input H1
5960
Function input H3
5970
Function input H4
5977
Function input H5
6008
Function input H6
6011
Function input H7
6020
Function extension module 1
6021
Function extension module 2
6022
Function extension module 3
6030
Relay output QX21 module 1
6031
Relay output QX22 module 1
6032
Relay output QX23 module 1
6033
Relay output QX21 module 2
6034
Relay output QX22 module 2
6035
Relay output QX23 module 2
6036
Relay output QX21 module 3
6037
Relay output QX22 module 3
6038
Relay output QX23 module 3
6040
Sensor input BX21 module 1
6041
Sensor input BX22 module 1
6042
Sensor input BX21 module 2
6043
Sensor input BX22 module 2
6044
Sensor input BX21 module 3
6045
Sensor input BX22 module 3
6046
Function input H2 module 1
6054
Function input H2 module 2
6062
Function input H2 module 3
6085
Function output P1
6600
Device address
6601
Segment address
380/617
Building Technologies Division
1
(No DHW)
None
None
None
None
None
None
None
None
None
Room thermostat
HC1
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
1
0
With operator terminals having a double display, the display also shows whether the
preselection is still the same or whether it has already been adapted (that is, if at least
one parameter has been changed).
When using operator terminals without double display, it may be necessary to switch to
the next parameter to see the required display.
Changed
At least one parameter of the preselection has been changed.
Unchanged
Parameters of the preselection have not yet been changed.
User Manual LMS14...
6 The settings in detail
2
3
(DHW storage
(Instantaneous
tank)
water heater)
None
None
DHW controlling
Instantaneous water
element Q3
heater controlling
element Q34
None
None
Sensor B31
None
None
None
None
None
None
DHW flow switch
None
None
None
None
Room thermostat
Room thermostat
HC1
HC1
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
1
1
0
0
4
(DHW
stratification
storage tank)
DHW intermediate
circuit pump Q33
DHW controlling
element Q3
None
Sensor B31
Sensor B36
None
None
None
None
Room thermostat
HC1
None
None
Multifunctional
None
None
Collector pump Q5
None
None
None
None
None
None
None
None
Sensor B6
None
None
None
None
None
None
None
None
None
1
0
CC1U7471en