Operator unit
flow sensor B63 ¦ Solar return sensor B64 ¦ Primary
exch sensor B26
6046
Function input H2 module 1
None ¦ Optg mode change HCs+DHW ¦ Optg mode
changeover DHW ¦ Optg mode changeover HCs ¦
Optg mode changeover HC1 ¦ Optg mode
changeover HC2 ¦ Optg mode changeover HC3 ¦
Heat generation lock ¦ Error/alarm message ¦
Consumer request VK1 ¦ Consumer request VK2 ¦
Release swi pool source heat ¦ Excess heat
discharge ¦ Release swi pool solar ¦ Operating level
DHW ¦ Operating level HC1 ¦ Operating level HC2 ¦
Operating level HC3 ¦ Room thermostat HC1 ¦
Room thermostat HC2 ¦ Room thermostat HC3 ¦
DHW flow switch ¦ DHW thermostat ¦ Limit
thermostat HC ¦ Start prevention ¦ Boiler flow
switch ¦ Boiler pressure switch ¦ Consumer request
VK1 10V ¦ Consumer request VK2 10V ¦ Pressure
measurement 10V ¦ Output request 10V
6047
Contact type H2 module 1
NC ¦ NO
6049
Voltage value 1 H2 module 1
6050
Function value 1 H2 module 1
6051
Voltage value 2 H2 module 1
6052
Function value 2 H2 module 1
6054
Function input H2 module 2
None ¦ Optg mode change HCs+DHW ¦ Optg mode
changeover DHW ¦ Optg mode changeover HCs ¦
Optg mode changeover HC1 ¦ Optg mode
changeover HC2 ¦ Optg mode changeover HC3 ¦
Heat generation lock ¦ Error/alarm message ¦
Building Technologies Division
Operating line
ACS420
return sensor B70 ¦ Pool sensor B13 ¦
Solar flow sensor B63 ¦ Solar return
sensor B64 ¦ Primary exch sensor B26
Function H2 module 1
None ¦ Optg mode change HCs+DHW ¦
Optg mode changeover DHW ¦ Optg mode
changeover HCs ¦ Optg mode changeover
HC1 ¦ Optg mode changeover HC2 ¦ Optg
mode changeover HC3 ¦ Heat generation
lock ¦ Error/alarm message ¦ Consumer
request VK1 ¦ Consumer request VK2 ¦
Release swi pool source heat ¦ Excess
heat discharge ¦ Release swi pool solar ¦
Operating level DHW ¦ Operating level
HC1 ¦ Operating level HC2 ¦ Operating
level HC3 ¦ Room thermostat HC1 ¦ Room
thermostat HC2 ¦ Room thermostat HC3 ¦
DHW flow switch ¦ DHW thermostat ¦ Limit
thermostat HC ¦ Start prevention ¦ Boiler
flow switch ¦ Boiler pressure switch ¦
Consumer request VK1 10V ¦ Consumer
request VK2 10V ¦ Pressure measurement
10V ¦ Output request 10V
Contact type H2 mod1
normal closed ¦ normal opened
VoltageValue1 H2 mod1
Funct value 1 H2 mod1
VoltageValue2 H2 mod1
Funct value 2 H2 mod1
Function H2 module2
None ¦ Optg mode change HCs+DHW ¦
Optg mode changeover DHW ¦ Optg mode
changeover HCs ¦ Optg mode changeover
HC1 ¦ Optg mode changeover HC2 ¦ Optg
mode changeover HC3 ¦ Heat generation
User Manual LMS14...
5 Handling
ACS700/ACS790
return sensor B70 ¦ Pool sensor B13 ¦
Solar flow sensor B63 ¦ Solar return
sensor B64 ¦ Primary exch sensor B26
Function input H2 module 1
None ¦ Optg mode change HCs+DHW ¦
Optg mode changeover DHW ¦ Optg mode
changeover HCs ¦ Optg mode changeover
HC1 ¦ Optg mode changeover HC2 ¦ Optg
mode changeover HC3 ¦ Heat generation
lock ¦ Error/alarm message ¦ Consumer
request VK1 ¦ Consumer request VK2 ¦
Release swi pool source heat ¦ Excess
heat discharge ¦ Release swi pool solar ¦
Operating level DHW ¦ Operating level
HC1 ¦ Operating level HC2 ¦ Operating
level HC3 ¦ Room thermostat HC1 ¦ Room
thermostat HC2 ¦ Room thermostat HC3 ¦
DHW flow switch ¦ DHW thermostat ¦ Limit
thermostat HC ¦ Start prevention ¦ Boiler
flow switch ¦ Boiler pressure switch ¦
Consumer request VK1 10V ¦ Consumer
request VK2 10V ¦ Pressure measurement
10V ¦ Output request 10V
Contact type H2 module 1
normal closed ¦ normal opened
Voltage value 1 H2 module 1
Funct value 1 H2 module 1
Voltage value 2 H2 module 1
Funct value 2 H2 module 1
Function input H2 module 2
None ¦ Optg mode change HCs+DHW ¦
Optg mode changeover DHW ¦ Optg mode
changeover HCs ¦ Optg mode changeover
HC1 ¦ Optg mode changeover HC2 ¦ Optg
mode changeover HC3 ¦ Heat generation
None
normal opened
0
0
10
0
-1000
5000
0
0
10
0
-1000
5000
None
CC1U7471en
-
Volt
-
Volt
-
91/617
28.01.2015