Albatros2 boiler management unit
Table of Contents

Advertisement

Operator unit
6985
SW diagnostic code 19
6986
Burner control phase 19
6990
History 20
6993
Error code 20
No error ¦ Error 1 ...
6995
SW diagnostic code 20
6996
Burner control phase 20
6999
Reset history
No ¦ Yes
Maintenance/special operation
7040
Burner hours interval
7041
Burner hrs since maintenance
7042
Burner start interval
7043
Burner starts since maint
7044
Maintenance interval
7045
Time since maintenance
7050
Fan speed ionization current
7051
Message ionization current
No ¦ Yes
7130
Chimney sweep function
Off ¦ On
7131
Burner output
Partial load ¦ Full load ¦ Max heating load
7140
Manual control
Off ¦ On
7143
Controller stop function
Off ¦ On
7145
Controller stop setpoint
7146
Deaeration function
Off ¦ On
7147
Type of venting
Building Technologies Division
Operating line
ACS420
StrDia19
StrPn19
Time ErrorHistory 20
ErrorCode History 20
No error ¦ Error 1 ...
StrDia20
StrPn20
Reset ErrorHistory
No ¦ Yes
BurnHours MaintInt
BurnHours sinceMaint
BurnStarts MaintInt
BurnStarts sinceMaint
Maintenance Interval
Time sinceMaint
FanSp ServiceThresh
IonCurr ServMessage
No ¦ Yes
ChimneySweep function
Off ¦ On
Chimney BurnerOutput
Low-fire ¦ High-fire ¦ Max heating load
Manual operation
Off ¦ On
Contr stop function
Off ¦ On
Contr stop setpoint
Deaeration function
Off ¦ On
Type of venting
User Manual LMS14...
5 Handling
ACS700/ACS790
SW diagnostic code 19
Burner control phase 19
Time stamp error history entry 20
Error code history entry 20
No error ¦ Error 1 ...
SW diagnostic code 20
Burner control phase 20
Reset error history
No ¦ Yes
Burner hours run maintenance
interval
Burner hours run since
maintenance
Burner starts maintenance interval
Burner starts since maintenance
Maintenance interval
Time since maintenance
Fan speed threshold for service
message
Ionization current service message
No ¦ Yes
Chimney sweep function
Off ¦ On
Chimney sweep function burner
output
Low-fire ¦ High-fire ¦ Max heating load
Manual operation
Off ¦ On
Controller stop function
Off ¦ On
Controller stop setpoint
Deaeration function
Off ¦ On
Type of venting
-
0
65535
-
0
255
-
No error 0
65535
-
0
65535
-
0
255
No
  
   / 100
10000
0
0
10000
  
   / 100
65500
0
0
65535
  
   / 1
240
0
0
240
0
0
10000
No
Off
Max heating load
Off
Off
50
0
100
On
None
CC1U7471en
-
-
-
-
-
-
h
h
-
-
Months
Months
-1
min
-
-
-
-
%
-
-
101/617