12 Functional Descriptions
12.20.7 Retraction
12.20.7
The retraction motion can be parameterized and programmed.
The following diagram shows the possible sources and the associated reactions for the
extended, parameterizable and open-loop controlled retraction without giving the programmable
retraction motions.
Axis/spindle-
specific sources
DC link warning threshold
Generator minimum
speed limit
NC MD 530* 596*
1 MD byte
for enabling
per axis/spindle
0: Signal not operative
1: Signal operative
Axis/spindle-
specific interface
Retraction signal
Programmable retraction as open-loop control function
There are two categories of retraction, i.e.
•
as an open-loop control function and
•
as an autonomous drive function.
Sources
There are four source areas for the retraction process:
•
Internal axis/spindle-specific sources,
•
Internal sources specific to channel/mode group or general sources,
•
External sources via HW inputs,
•
Communications failure (autonomous drive sources which initiate generator-mode braking
of the drive).
12–222
More user manuals on
Retraction
Channel-specific/
general sources
Emergency retraction
threshold FA
1 MD byte
for enabling
per channel
NC MD 529* 592*
1 MD byte
for enabling
per axis/spindle
and channel
0: Reaction is not initiated
DB 29 - DB 31
1: Reaction is initiated
e.g.: Mode group stop
e.g.: Alarm
e.g.: Internal retraction
ManualsBase.com
External sources
Mode group stop
EMERGENCY
HW input
STOP
(1 byte per mode group)
NC MD 920*
1 MD byte
for enabling
•
Mixed I/O
per channel
•
CSB
NC MD
NC MD 918*
528* 588*
1 MD byte
per axis/spindle
and channel
HW output
One byte per mode group
© Siemens AG 1992 All Rights Reserved
10.94
NC MD 922*
NC MD 916*
Channel-specific
interface DB 10-DB 15
6FC5197- AA50
SINUMERIK 840C (IA)