Removing And Replacing The Cisco Asr 1004 Router Power Supplies - Cisco ASR 1013 Hardware Installation Manual

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Step 11
Replace the terminal block plastic cover, which is slotted and keyed to fit correctly over the terminal block; then tighten
the black screw (use the screwdriver to tighten the screw to a torque of 5 in-lbs / 1 per). See the following figure.
Figure 273: Cisco ASR 1006 Router DC Power Supply Terminal Block Plastic Cover and Switch
1
Step 12
Remove the tape from the circuit-breaker On/Off switch.
Step 13
Switch the circuit breaker On/Off switch to the On (|) position.
What to Do Next
The requirement for maximum torque applied to the power or ground Kepnuts must be 8 in-lb when the
Note
power or ground lug is not present.
This completes the procedure for installing the DC power supply into the Cisco ASR 1006 Router.
Removing and Replacing the Cisco ASR 1004 Router Power
Supplies
The Cisco ASR 1004 Router contains power supplies that are field replaceable units. This section contains
the following topics:

Removing and Replacing the Cisco ASR 1004 Router Power Supplies

DC power supply On/Off
switch
Cisco ASR 1000 Series Router Hardware Installation Guide
2
Terminal block plastic cover
black screw
555

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents