Removing and Replacing the Cisco ASR 1001-X Router Power Supplies

Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Statement 1003
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1030

Removing AC Power Supplies from the Cisco ASR 1001-X Router

This section describes how to remove an AC power supply from the Cisco ASR 1001-X Router. The
Cisco ASR 1001-X Router has two power supply slots, power supply slot 0 (PS0) next to the Standby
switch and power supply slot 1 (PS1) to the right, as shown in
The Cisco ASR 1001-X Router has redundant power supplies that can be hot-swapped.
Note
Follow these steps to remove an AC power supply from the Cisco ASR 1001-X Router:
At the rear of the router, ensure that the power switch is in the Standby position.
Step 1
Note
Step 2
Unplug the power cable from the power supply as shown in
Press the retaining latch towards the pull handle, grasp the handle with one hand, and pull the power
Step 3
supply out of the slot while supporting the weight of the power supply with the other hand, as shown in
Figure
Figure 7-1
Cisco ASR 1001-X Router Hardware Installation Guide
7-2
It is not required to place the power switch in the Standby position if you want to hot-swap a
single power supply.
7-2.
Removing the AC Power Supply Cable in Slot PS1