Installing Ac Input Power To Cisco Asr 1001 Router - Cisco ASR 1013 Hardware Installation Manual

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Installing AC Input Power to Cisco ASR 1001 Router

LED Color and State
Blinking amber, at the rate of one blink per second
Off
This section contains the following topics:
The covers are an integral part of the safety design of the product. Do not operate the unit without the
Warning
covers installed. Statement 1077
When you install the unit, the ground connection must always be made first and disconnected last. Statement
Warning
1046
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Statement 1003
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1030
Installing AC Input Power to Cisco ASR 1001 Router
The Cisco ASR 1001 Router has two AC power supplies in the rear of the chassis. The input receptacle is an
IEC60320 C14 type of filtered AC inlet. The current rating on the connector is 10 A.
Do not install the power supplies with the chassis cover off.
Warning
Cisco ASR 1000 Series Router Hardware Installation Guide
446
Cisco ASR 1001 Router Overview and Installation
Description
A power supply warning event has occurred, but the
power supply can continue to operate. The warning
event can be temperature, voltage, current, or fan
operating outside the normal operating range.
Power supply is shut down.