Ac Power System Output Voltage Alarm Range For Cisco Asr 1002 Router; Cisco Asr 1002 Router -48 Vdc Power Supply - Cisco ASR 1013 Hardware Installation Manual

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Cisco ASR 1002 Router –48 VDC Power Supply
Table 24: Cisco ASR 1002 Router Power Supply LEDs
LED Label
INPUT OK
FAN OK
OUTPUT FAIL

AC Power System Output Voltage Alarm Range for Cisco ASR 1002 Router

The AC power supply output voltage alarm occurs when the output voltage is below the low end of the
minimum or above the high end of the maximum limits shown in the following table.
Table 25: Cisco ASR 1002 Router AC Power Supply Output Voltage Alarm Range
Power Supply Type
12 V
3.3 V
Cisco ASR 1002 Router –48 VDC Power Supply
This section provides information about the –48 VDC power supplies on the rear of the Cisco ASR 1002
Router. The recommended branch circuit breaker for the Cisco ASR 1002 Router –48 VDC power supply is
Cisco ASR 1000 Series Router Hardware Installation Guide
68
LED
Power supply activity
Power supply fan activity
A bi-color LED indicates fan
status.
Power supply activity
Minimum
10.0 to 11.2V
2.6 to 3.0 V
Cisco ASR 1000 Series Routers Component Overview
Color
Green
None
Green
Red
Red
Description
The AC input voltage is greater
than 85V.
If the LED is not illuminated,
then either the input voltage is
less than 70V, or the power
supply is turned off.
If the AC input voltage is
between 70V and 85V, the
INPUT OK LED can be on, off,
or flashing.
All fans are operational.
A fan failure is detected.
If the INPUT OK LED is
illuminated, this LED is red if
the DC output voltages are
below the minimum limit or
above the maximum limit.
If the INPUT OK LED is not
illuminated, this LED might be
off or red.
Maximum
12.8 to 13.8 V
None

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents