Cisco Asr 1000 Series Router Hardware Installation Guide - Cisco ASR 1013 Hardware Installation Manual

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Cisco ASR 1000 Series Routers Component Overview
The +24 VDC power supply product is labeled at +27 VDC input because the typical battery float voltage
Note
is +27V; but generically, these power systems can be labeled +24 V and referred to as +24 VDC (see the
following figure for more information).
Figure 19: Cisco ASR 1002 Router Rear View With +24 VDC Power Supply Terminal Block
1
2
The following table describes the power supply LEDs and connectors on the rear of the chassis.
Table 29: Cisco ASR 1002 Router +24 VDC Power Supply LEDs
LED Label
OUTPUT FAIL
Positive (+) lead
Negative (-) lead
LED
Power supply activity
Cisco ASR 1002 Router +24 VDC Power Supply
6
7
Color
Red

Cisco ASR 1000 Series Router Hardware Installation Guide

GROUND (GND) LEAD
+27VDC label
Description
When the LED is off, it signals
that the +24 VDC output
voltage are within the normal
operating range. Output voltage
between the minimum and
maximum limits will not create
an output fail alarm, and output
voltages below the minimum or
above the maximum will create
an Output Fail alarm.
When you turn the power
supply on, the red LED
illuminates for two to three
seconds to test LED operation
before going off.
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents