Cisco ASR 1013 Router Overview and Installation
• CAB-US520-C19-US—NEMA 5-15 to IEC-C19 14ft US
The Cisco ASR 1013 Router modular chassis supports redundant power entry modules (PEMs). At least one
PEM in each 1+1 redundant power supply zone must be functioning to power the zone and both zones must
be functional. In the event of a single fan failure, the remaining fans are sufficient to cool the entire chassis
although fan speed may have to be increased.
The Cisco ASR 1013 Router system is configured in a dual zone 1+1 power supply configuration. For ASR
1013 router power consumption specifications, see the
page A-14
The following items list the maximum input and output of the system power consumption for the two power
zones in the Cisco ASR 1013 Router:
• Maximum input (DC): 4,200W
• Maximum input (AC – High Line): 4,000 W
• Maximum output (DC and AC – High Line): 3,390 W
Note
At least one power supply in each of the two power supply zones must be powered on before the software
boots up. This prevents the route processor from detecting a power supply failure in a zone that is not
being used to power the active route processor. If you plan to connect the four power supplies to two
independent circuits for redundancy, you must ensure that a power supply from each power supply zone
is connected to each circuit. PS0 and PS1 are in power supply zone 0, and PS2 and PS3 are in power
supply zone 1. In this scenario, for example, PS0 and PS2 can be connected to one circuit and PS1 and
PS3 can be connected to the other circuit. Alternatively, PS0 and PS3 can be connected to one circuit and
PS1 and PS2 can be connected to the other circuit.
Detailed instructions for removing and replacing the Cisco ASR 1000 Series AC and DC power supplies
Note
are in the
.

Connecting AC Input Power to Cisco ASR 1013 Router

Follow these steps to connect an AC-input power supply to the Cisco 1013 chassis:
SUMMARY STEPS
1. At the rear of the chassis, check that the power switch on the power supply is in the Standby position.
2. Plug the power cable into the inlet.
3. Plug the AC power supply cable into the AC power source.
.
"Removing and Replacing the Cisco ASR 1013 Router Power Supplies" section on page 14-93
Connecting AC Input Power to Cisco ASR 1013 Router