Troubleshooting The Shared Port Adapter - Cisco ASR 1013 Hardware Installation Manual

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Troubleshooting Initial Startup Problems
Table 140: Troubleshooting the Cooling Subsystem
Symptom
System shuts down, some fans may
or may not continue to rotate, and
this error message is displayed:
Queued messages:
%ENVM-1-SHUTDOWN:
Environmental Monitor
initiated shutdown
This error message indicates that
the system has detected an
overtemperature condition or
out-of-tolerance power condition
inside the chassis.
Multiple fan failure
System shuts down, and the
following error message is
displayed:
Queued messages:
%ENVM-1-SHUTDOWN:
Environmental Monitor
initiated shutdown
This error message indicates that
the system has detected an
over-temperature condition or
out-of-tolerance power condition
inside the chassis.
Note

Troubleshooting the Shared Port Adapter

Use the information in the following table to isolate problems with the shared port adapter.
Possible Cause
To determine if the fans are
operating, listen for them. In noisy
environments, place your hand on
the rear of the chassis to feel if air
is being forced out the vents.
Fan speed dropped below the fan
fail speed.
Heated exhaust air from other
equipment is entering the routers
inlet vents.
The error message could indicate
a faulty component or temperature
sensor. Before the system shuts
down, use the show env all
command to display the internal
chassis environment.
If an environmental shutdown
results from an out-of-tolerance
power condition, the system shuts
down.
The system fans may
continue to operate
although the system shuts
down.
Troubleshooting the Shared Port Adapter
• One or more fans are not
operating.
• The fans are operating too
slowly.
• The power supply is not
operating.
Cisco ASR 1000 Series Router Hardware Installation Guide
Possible Solution
Contact a service representative.
• Identify and log the failed fan
PEM location.
• Replace the PEM.
Move other equipment or the router
to ensure proper airflow.
Contact a service representative.
If the system still fails to come up
when the power supply is
connected to a different power
source with a new power cable, the
power supply is probably faulty.
Contact a service representative.
651

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents