Power Cords Supported By The Cisco Asr 1004 Router - Cisco ASR 1013 Hardware Installation Manual

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Cisco ASR 1004 Router Overview and Installation
Cisco ASR 1000
Series Router
DC Power
Supply
For example, the
Cisco ASR 1002
Router –48
VDC power
supply, with 16
Amp input
rating must use
an AWG #12
gauge wire for a
20 A circuit
breaker and an
AWG #10 gauge
wire for a 30 A
circuit breaker.
All Cisco ASR 1000 Series Router AC power supplies must be connected to a branch circuit that does
Note
not exceed 20 A.
Detailed instructions for removing and replacing the Cisco ASR 1000 Series AC and DC power supplies
Note
are in

Power Cords Supported by the Cisco ASR 1004 Router

Table 51: Power Cords Supported by the Cisco ASR 1004 Router , on page 209
supported by the Cisco ASR 1004 Router.
Table 51: Power Cords Supported by the Cisco ASR 1004 Router
Power Cord Item Number
CAB-AC-RA
CAB-AC10A-90L-AU
CAB-AC10A-90L-EU
CAB-AC10A-90L-IT
System Input
Rating (Amps)
Chapter 14, "Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers."
Power Cords Supported by the Cisco ASR 1004 Router
Circuit Breaker
AWG # Wire
Amps
Description
Power Cord, 110 V, Right Angle
10 A AC Power Cord, Left Angle (Australia) (bundle
option)
10 A AC Power Cord, Left Angle (Europe) (bundle
option)
10 A AC Power Cord, Left Angle (Italy) (bundle
option)
Cisco ASR 1000 Series Router Hardware Installation Guide
lists the power cords that are
209

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents