3. To complete the installation, repeat these steps in reverse order.
4. Perform a lamp calibration.

Replacing the douser motor

Estimated Replacement Time: 8 minutes + 10 minute calibration
1. Remove the lamp, if installed (on page 60).
2. Remove the rear cover (on page 44).
3. Disconnect the douser motor harness (P94) from the integrated motor control board (IMCB)
and release it from the routing clips.
4. Remove the two screws securing the motor.
5. Remove the motor.
6. To install the douser motor, orient the motor with the harness protruding from bottom.
7. To complete the installation, repeat these steps in reverse order.
8. Perform a lamp calibration.

Replacing the ceramic douser plate

Estimated Replacement Time: 9 minutes + 10 minute calibration
1. Remove the lamp, if installed (on page 60).
2. Remove the rear cover (on page 44).
3. Remove the douser motor (on page 81).
4. Swing the douser blade out of the projector to access the screws.
Roadie 4K35 and 4K45 Service Manual
020-101694-03 Rev. 1 (01-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©
Parts and module replacement
81