Ceramic Plate On Douser Blade; Douser Motor - Christie D4K25 Service Manual

Hide thumbs Also See for D4K25:
Table of Contents

Advertisement

Section 5: Parts and Module Replacement

5.12.2 Ceramic Plate on Douser Blade

(Estimated Replacement Time: 30 minutes + 10 minute LampLOC™ Alignment)
The 3"x3" Ceramic Plate is located in the lamp compartment and mounted to
the douser blade. It is used to absorb heat from the light emitted by the lamp.
1. Remove lamp door. See
2. Remove lamp. See
3. Remove the four, #2 Phillips
douser blade (Figure 5-37).
4. When installing, repeat instructions in reverse. Once installed, perform
LampLOC
page
3-3.

5.12.3 Douser Motor

(Estimated Replacement Time: 30 minutes + 10 minute LampLOC™
Alignment)
The Douser Motor is located in the lamp compartment behind the reflector assembly.
1. Remove Lamp Door. See
Door, on page 5-8.
2. Remove Lamp. See
page 5-30.
3. Disconnect the douser motor harness
(P94) on the IMCB.
4. Remove two, #2 Phillips
securing the Douser Motor to the
mounting bracket. A short stubby
screwdriver is recommended to reach
the screws (Figure 5-38).
5. When installing, repeat instructions in
reverse. Make sure to route the douser
motor harness through the clips that run
along the projector frame to prevent it
from falling into the lamp area. Once installed, perform LampLOC
5-28
5.4.7 Lamp Door, on page 5-8.
5.12.5 Lamp, on page
screws securing the ceramic plate to the
alignment. See
3.3 Adjusting Lamp Position (LampLOC™), on
5.4.7 Lamp
5.12.5 Lamp, on
screws
5-30.
Figure 5-38 Douser Motor
Figure 5-37 Ceramic Plate
alignment.
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)