6.5

Control Panel Inside Temperature and GOT Installation Angle

6.5.1

GT27

Install the GOT with its display section positioned as shown below.
Using the GOT with the installation angle other than the following accelerates the deterioration of the GOT.
■1. GT27
When a multimedia unit (GT27-MMR-Z), MELSECNET/H communication unit (GT15-J71LP23-25, GT15-J71BR13), or
CC-Link communication unit (GT15-J61BT13) is mounted, the operating ambient temperature must be 5°C lower than
the maximum temperature described in Section 3.1 General Specifications.
(1) Installing the GOT horizontally
When the GOT is installed at any angle from 60 ° to 105 °, the control panel inside temperature must be within 55 °C.
When the GOT is installed at any angle outside the range from 60 ° to 105 °, the control panel inside temperature
must be within 40 °C.
(2) Installing the GOT vertically
When the GOT is installed a 90° angle, , the control panel inside temperature must be within 55°C.
When the GOT is installed at any angle other than 90°, the control panel inside temperature must be within 40°C.
6 - 26

6.5 Control Panel Inside Temperature and GOT Installation Angle

GOT
Display
section
Control panel
or others
GOT
Display
section
Control panel
or others
105°
60°
90°