The following tables list the distance required between the GOT and the other devices.
The dimensions within the parentheses apply when no equipment generating radiated noise (such as a contactor) or
heat is installed near the GOT.
However, always keep the ambient temperature of the GOT to 55 °C or lower.
Item
A
B
C
D
*1
E
*1
When opening or closing the battery cover: 72(2.83) or more.
GT25
GT2510-WX
51(2.01) or more
[23(0.91) or more]
Horizontal: 81(3.19) or more [23(0.91) or more]
Vertical: 53(2.09) or more [23(0.91 or more]
53(2.09) or more
[23(0.91) or more]
Horizontal: 53(2.09) or more [23(0.91) or more]
Vertical: 81(3.19) or more [23(0.91) or more]
100(3.94) or more
[20(0.79) or more]
6.4 Installation Position
Unit: mm (inch)
GT2507-W
64(2.52) or more
53(2.09) or more
[32(1.26) or more]