A Appendix
No.
Description
6503
>BLOCK 27 undervoltage pro-
tection (>BLOCK 27)
6505
>27-Switch current supervision
ON (>27 I SUPRVSN)
6506
>BLOCK 27-1 Undervoltage pro-
tection (>BLOCK 27-1)
6508
>BLOCK 27-2 Undervoltage pro-
tection (>BLOCK 27-2)
6509
>Failure: Feeder VT
(>FAIL:FEEDER VT)
6510
>Failure: Busbar VT (>FAIL: BUS
VT)
6513
>BLOCK 59-1 overvoltage pro-
tection (>BLOCK 59-1)
6530
27 Undervoltage protection
switched OFF (27 OFF)
6531
27 Undervoltage protection is
BLOCKED (27 BLOCKED)
6532
27 Undervoltage protection is
ACTIVE (27 ACTIVE)
6533
27-1 Undervoltage picked up
(27-1 picked up)
6534
27-1 Undervoltage PICKUP
w/curr. superv (27-1 PU CS)
6537
27-2 Undervoltage picked up
(27-2 picked up)
6538
27-2 Undervoltage PICKUP
w/curr. superv (27-2 PU CS)
6539
27-1 Undervoltage TRIP (27-1
TRIP)
6540
27-2 Undervoltage TRIP (27-2
TRIP)
6565
59-Overvoltage protection
switched OFF (59 OFF)
6566
59-Overvoltage protection is
BLOCKED (59 BLOCKED)
6567
59-Overvoltage protection is
ACTIVE (59 ACTIVE)
6568
59 picked up (59-1 picked up)
6570
59 TRIP (59-1 TRIP)
6571
59-2 Overvoltage V>> picked up
(59-2 picked up)
6573
59-2 Overvoltage V>> TRIP (59-2
TRIP)
6801
>BLOCK Startup Supervision
(>BLK START-SUP)
6805
>Rotor locked (>Rotor locked)
6811
Startup supervision OFF
(START-SUP OFF)
6812
Startup supervision is BLOCKED
(START-SUP BLK)
6813
Startup supervision is ACTIVE
(START-SUP ACT)
6821
Startup supervision TRIP
(START-SUP TRIP)
687
Function
Type
of In-
for-
matio
n
27/59 O/U Volt.
SP
*
27/59 O/U Volt.
SP
On
Off
27/59 O/U Volt.
SP
On
Off
27/59 O/U Volt.
SP
On
Off
Measurem.Superv
SP
On
Off
Measurem.Superv
SP
On
Off
27/59 O/U Volt.
SP
*
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
48/66 Motor
SP
*
48/66 Motor
SP
*
48/66 Motor
OUT
On
Off
48/66 Motor
OUT
On
Off
48/66 Motor
OUT
On
Off
48/66 Motor
OUT
*
Log Buffers
Configurable in Matrix
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED
On
*
LED
Off
*
*
LED
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
on
m
LED
on
*
LED
*
*
LED
On
*
LED
Off
*
*
LED
On
*
LED
Off
on
m
LED
On
*
LED
Off
on
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED
On
*
LED
Off
*
*
LED
on
m
LED
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
IEC 60870-5-103
BO
74
3
1
Yes
BO
74
5
1
Yes
BO
74
6
1
Yes
BO
74
8
1
Yes
BO
74
9
1
Yes
BO
74
10
1
Yes
BO
74
13
1
Yes
BO
74
30
1
Yes
BO
74
31
1
Yes
BO
74
32
1
Yes
BO
74
33
2
Yes
BO
74
34
2
Yes
BO
74
37
2
Yes
BO
74
38
2
Yes
BO
74
39
2
Yes
BO
74
40
2
Yes
BO
74
65
1
Yes
BO
74
66
1
Yes
BO
74
67
1
Yes
BO
74
68
2
Yes
BO
74
70
2
Yes
BO
BO
BO
BO
BO
169
51
1
Yes
BO
169
52
1
Yes
BO
169
53
1
Yes
BO
169
54
2
Yes