Siemens siprotec SJ62 User Manual page 649

Multi-functional protective relay with local control
Table of Contents

Advertisement

A Appendix
Addr.
Parameter
1505
67-1 DELAY
1507
67-TOC PICKUP
1508
67 TIME DIAL
1509
67 TIME DIAL
1510
67-TOC Drop-out
1511
67- IEC CURVE
1512
67- ANSI CURVE
1513A
MANUAL CLOSE
1514A
67 active
1516
67 Direction
1518A
67 T DROP-OUT
1519A
ROTATION ANGLE
1530
67
1531
MofPU Res T/Tp
1601
FCT 67N/67N-TOC
1602
67N-2 PICKUP
1603
67N-2 DELAY
1604
67N-1 PICKUP
1605
67N-1 DELAY
1607
67N-TOC PICKUP
1608
67N-TOC T-DIAL
1609
67N-TOC T-DIAL
1610
67N-TOC DropOut
1611
67N-TOC IEC
1612
67N-TOC ANSI
1613A
MANUAL CLOSE
1614A
67N active
1616
67N Direction
647
Function
C
0.00 .. 60.00 sec; ∞
67 Direct. O/C
67 Direct. O/C
1A
0.10 .. 4.00 A
5A
0.50 .. 20.00 A
0.05 .. 3.20 sec; ∞
67 Direct. O/C
0.50 .. 15.00 ; ∞
67 Direct. O/C
67 Direct. O/C
Instantaneous
Disk Emulation
67 Direct. O/C
Normal Inverse
Very Inverse
Extremely Inv.
Long Inverse
67 Direct. O/C
Very Inverse
Inverse
Short Inverse
Long Inverse
Moderately Inv.
Extremely Inv.
Definite Inv.
67 Direct. O/C
67-2 instant.
67-1 instant.
67-TOC instant.
Inactive
67 Direct. O/C
with 79 active
always
67 Direct. O/C
Forward
Reverse
67 Direct. O/C
0.00 .. 60.00 sec
-180 .. 180 °
67 Direct. O/C
1.00 .. 20.00 I/Ip; ∞
67 Direct. O/C
0.01 .. 999.00 TD
0.05 .. 0.95 I/Ip; ∞
67 Direct. O/C
0.01 .. 999.00 TD
67 Direct. O/C
OFF
ON
0.05 .. 35.00 A; ∞
67 Direct. O/C
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
67 Direct. O/C
0.05 .. 35.00 A; ∞
67 Direct. O/C
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
67 Direct. O/C
67 Direct. O/C
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
0.05 .. 3.20 sec; ∞
67 Direct. O/C
0.50 .. 15.00 ; ∞
67 Direct. O/C
67 Direct. O/C
Instantaneous
Disk Emulation
67 Direct. O/C
Normal Inverse
Very Inverse
Extremely Inv.
Long Inverse
67 Direct. O/C
Very Inverse
Inverse
Short Inverse
Long Inverse
Moderately Inv.
Extremely Inv.
Definite Inv.
67 Direct. O/C
67N-2 instant.
67N-1 instant.
67N-TOC instant
Inactive
67 Direct. O/C
always
with 79 active
67 Direct. O/C
Forward
Reverse
Setting Options
Default Setting
0.50 sec
1.00 A
5.00 A
0.50 sec
5.00
Disk Emulation
Normal Inverse
Very Inverse
67-2 instant.
always
Forward
0.00 sec
45 °
OFF
0.50 A
2.50 A
0.10 sec
0.20 A
1.00 A
0.50 sec
0.20 A
1.00 A
0.20 sec
5.00
Disk Emulation
Normal Inverse
Very Inverse
67N-2 instant.
always
Forward
Comments
67-1Time Delay
67-TOC Pickup
67-TOC Time Dial
67-TOC Time Dial
Drop-Out Characteristic
IEC Curve
ANSI Curve
Manual Close Mode
67 active
Phase Direction
67 Drop-Out Time Delay
Rotation Angle of Reference
Voltage
67
Multiple of Pickup <-> T/Tp
67N, 67N-TOC Ground Time
Overcurrent
67N-2 Pickup
67N-2 Time Delay
67N-1 Pickup
67N-1 Time Delay
67N-TOC Pickup
67N-TOC Time Dial
67N-TOC Time Dial
Drop-Out Characteristic
IEC Curve
ANSI Curve
Manual Close Mode
67N active
Ground Direction
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015