A Appendix
No.
Description
1825
51 TRIP (51 TRIP)
1831
50N-2 picked up (50N-2 picked
up)
1832
50N-2 Time Out (50N-2 TimeOut) 50/51 Overcur.
1833
50N-2 TRIP (50N-2 TRIP)
1834
50N-1 picked up (50N-1 picked
up)
1835
50N-1 Time Out (50N-1 TimeOut) 50/51 Overcur.
1836
50N-1 TRIP (50N-1 TRIP)
1837
51N picked up (51N picked up)
1838
51N Time Out (51N TimeOut)
1839
51N TRIP (51N TRIP)
1840
Phase A inrush detection (PhA
InrushDet)
1841
Phase B inrush detection (PhB
InrushDet)
1842
Phase C inrush detection (PhC
InrushDet)
1843
Cross blk: PhX blocked PhY
(INRUSH X-BLK)
1851
50-1 BLOCKED (50-1
BLOCKED)
1852
50-2 BLOCKED (50-2
BLOCKED)
1853
50N-1 BLOCKED (50N-1
BLOCKED)
1854
50N-2 BLOCKED (50N-2
BLOCKED)
1855
51 BLOCKED (51 BLOCKED)
1856
51N BLOCKED (51N BLOCKED) 50/51 Overcur.
1866
51 Disk emulation Pickup (51
Disk Pickup)
1867
51N Disk emulation picked up
(51N Disk Pickup)
1994
Cold-Load-Pickup switched OFF
(CLP OFF)
1995
Cold-Load-Pickup is BLOCKED
(CLP BLOCKED)
1996
Cold-Load-Pickup is RUNNING
(CLP running)
1997
Dynamic settings are ACTIVE
(Dyn set. ACTIVE)
2604
>BLOCK 67/67-TOC (>BLK
67/67-TOC)
2614
>BLOCK 67N/67N-TOC (>BLK
67N/67NTOC)
2615
>BLOCK 67-2 (>BLOCK 67-2)
2616
>BLOCK 67N-2 (>BLOCK 67N-2) 67 Direct. O/C
2621
>BLOCK 67-1 (>BLOCK 67-1)
2622
>BLOCK 67-TOC (>BLOCK 67-
TOC)
681
Function
Type
of In-
for-
matio
n
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
OUT
On
Off
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
ColdLoadPickup
OUT
On
Off
ColdLoadPickup
OUT
On
Off
ColdLoadPickup
OUT
On
Off
ColdLoadPickup
OUT
On
Off
67 Direct. O/C
SP
*
67 Direct. O/C
SP
*
67 Direct. O/C
SP
*
SP
*
67 Direct. O/C
SP
*
67 Direct. O/C
SP
*
Log Buffers
Configurable in Matrix
on
m
LED
On
*
LED
Off
*
*
LED
on
m
LED
On
*
LED
Off
*
*
LED
on
m
LED
On
*
LED
Off
*
*
LED
on
m
LED
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
*
*
LED
*
*
LED
*
*
LED
On
*
LED
Off
*
*
LED
*
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
IEC 60870-5-103
BO
60
58
2
Yes
BO
60
59
2
Yes
BO
60
60
2
Yes
BO
160
93
2
No
BO
60
62
2
Yes
BO
60
63
2
Yes
BO
160
92
2
No
BO
60
64
2
Yes
BO
60
65
2
Yes
BO
60
66
2
Yes
BO
60
101
2
Yes
BO
60
102
2
Yes
BO
60
103
2
Yes
BO
60
104
2
Yes
BO
60
105
1
Yes
BO
60
106
1
Yes
BO
60
107
1
Yes
BO
60
108
1
Yes
BO
60
109
1
Yes
BO
60
110
1
Yes
BO
BO
BO
60
244
1
Yes
BO
60
245
1
Yes
BO
60
246
1
Yes
BO
60
247
1
Yes
BO
BO
BO
63
73
1
Yes
BO
63
74
1
Yes
BO
63
1
1
Yes
BO
63
2
1
Yes