Addr.
Parameter
1211
51 IEC CURVE
1212
51 ANSI CURVE
1213A
MANUAL CLOSE
1214A
50-2 active
1215A
50 T DROP-OUT
1230
51/51N
1231
MofPU Res T/Tp
1301
FCT 50N/51N
1302
50N-2 PICKUP
1303
50N-2 DELAY
1304
50N-1 PICKUP
1305
50N-1 DELAY
1307
51N PICKUP
1308
51N TIME DIAL
1309
51N TIME DIAL
1310
51N Drop-out
1311
51N IEC CURVE
1312
51N ANSI CURVE
1313A
MANUAL CLOSE
1314A
50N-2 active
1315A
50N T DROP-OUT
1330
50N/51N
1331
MofPU Res T/TEp
1501
FCT 67/67-TOC
1502
67-2 PICKUP
1503
67-2 DELAY
1504
67-1 PICKUP
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
Function
C
50/51 Overcur.
Normal Inverse
Very Inverse
Extremely Inv.
Long Inverse
50/51 Overcur.
Very Inverse
Inverse
Short Inverse
Long Inverse
Moderately Inv.
Extremely Inv.
Definite Inv.
50/51 Overcur.
50-2 instant.
50 -1 instant.
51 instant.
Inactive
50/51 Overcur.
Always
with 79 active
50/51 Overcur.
0.00 .. 60.00 sec
1.00 .. 20.00 I/Ip; ∞
50/51 Overcur.
0.01 .. 999.00 TD
0.05 .. 0.95 I/Ip; ∞
50/51 Overcur.
0.01 .. 999.00 TD
50/51 Overcur.
ON
OFF
0.05 .. 35.00 A; ∞
50/51 Overcur.
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
50/51 Overcur.
0.05 .. 35.00 A; ∞
50/51 Overcur.
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
50/51 Overcur.
50/51 Overcur.
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
0.05 .. 3.20 sec; ∞
50/51 Overcur.
0.50 .. 15.00 ; ∞
50/51 Overcur.
50/51 Overcur.
Instantaneous
Disk Emulation
50/51 Overcur.
Normal Inverse
Very Inverse
Extremely Inv.
Long Inverse
50/51 Overcur.
Very Inverse
Inverse
Short Inverse
Long Inverse
Moderately Inv.
Extremely Inv.
Definite Inv.
50/51 Overcur.
50N-2 instant.
50N-1 instant.
51N instant.
Inactive
50/51 Overcur.
Always
With 79 Active
50/51 Overcur.
0.00 .. 60.00 sec
1.00 .. 20.00 I/Ip; ∞
50/51 Overcur.
0.01 .. 999.00 TD
0.05 .. 0.95 I/Ip; ∞
50/51 Overcur.
0.01 .. 999.00 TD
67 Direct. O/C
OFF
ON
0.10 .. 35.00 A; ∞
67 Direct. O/C
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
67 Direct. O/C
0.10 .. 35.00 A; ∞
67 Direct. O/C
1A
0.50 .. 175.00 A; ∞
5A
Setting Options
Default Setting
Normal Inverse
Very Inverse
50-2 instant.
Always
0.00 sec
ON
0.50 A
2.50 A
0.10 sec
0.20 A
1.00 A
0.50 sec
0.20 A
1.00 A
0.20 sec
5.00
Disk Emulation
Normal Inverse
Very Inverse
50N-2 instant.
Always
0.00 sec
OFF
2.00 A
10.00 A
0.10 sec
1.00 A
5.00 A
A.8 Settings
Comments
IEC Curve
ANSI Curve
Manual Close Mode
50-2 active
50 Drop-Out Time Delay
51/51N
Multiple of Pickup <-> T/Tp
50N, 51N Ground Time Overcur-
rent
50N-2 Pickup
50N-2 Time Delay
50N-1 Pickup
50N-1 Time Delay
51N Pickup
51N Time Dial
51N Time Dial
Drop-Out Characteristic
IEC Curve
ANSI Curve
Manual Close Mode
50N-2 active
50N Drop-Out Time Delay
50N/51N
Multiple of Pickup <-> T/TEp
67, 67-TOC Phase Time Over-
current
67-2 Pickup
67-2 Time Delay
67-1 Pickup
646