Siemens siprotec SJ62 User Manual page 680

Multi-functional protective relay with local control
Table of Contents

Advertisement

No.
Description
1023
Accumulation of interrupted
current Ph C (Σ Ic =)
1106
>Start Fault Locator (>Start Flt.
Loc)
1118
Flt Locator: secondary REAC-
TANCE (Xsec =)
1119
Flt Locator: Distance to fault (dist
=)
1123
Fault Locator Loop AG (FL Loop
AG)
1124
Fault Locator Loop BG (FL Loop
BG)
1125
Fault Locator Loop CG (FL Loop
CG)
1126
Fault Locator Loop AB (FL Loop
AB)
1127
Fault Locator Loop BC (FL Loop
BC)
1128
Fault Locator Loop CA (FL Loop
CA)
1132
Fault location invalid (Flt.Loc.in-
valid)
1201
>BLOCK 64 (>BLOCK 64)
1202
>BLOCK 50Ns-2 (>BLOCK
50Ns-2)
1203
>BLOCK 50Ns-1 (>BLOCK
50Ns-1)
1204
>BLOCK 51Ns (>BLOCK 51Ns)
1207
>BLOCK 50Ns/67Ns (>BLK
50Ns/67Ns)
1211
50Ns/67Ns is OFF (50Ns/67Ns
OFF)
1212
50Ns/67Ns is ACTIVE
(50Ns/67Ns ACT)
1215
64 displacement voltage pick up
(64 Pickup)
1217
64 displacement voltage element
TRIP (64 TRIP)
1221
50Ns-2 Pickup (50Ns-2 Pickup)
1223
50Ns-2 TRIP (50Ns-2 TRIP)
1224
50Ns-1 Pickup (50Ns-1 Pickup)
1226
50Ns-1 TRIP (50Ns-1 TRIP)
1227
51Ns picked up (51Ns Pickup)
1229
51Ns TRIP (51Ns TRIP)
1230
Sensitive ground fault detection
BLOCKED (Sens. Gnd block)
1264
Corr. Resistive Earth current
(IEEa =)
1265
Corr. Reactive Earth current
(IEEr =)
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
Function
Type
of In-
for-
matio
n
Statistics
VI
Fault Locator
SP
on
Fault Locator
VI
Fault Locator
VI
Fault Locator
OUT
*
Fault Locator
OUT
*
Fault Locator
OUT
*
Fault Locator
OUT
*
Fault Locator
OUT
*
Fault Locator
OUT
*
Fault Locator
OUT
*
Sens. Gnd Fault
SP
On
Off
Sens. Gnd Fault
SP
On
Off
Sens. Gnd Fault
SP
On
Off
Sens. Gnd Fault
SP
On
Off
Sens. Gnd Fault
SP
On
Off
Sens. Gnd Fault
OUT
On
Off
Sens. Gnd Fault
OUT
On
Off
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
*
Sens. Gnd Fault
OUT
On
Off
Sens. Gnd Fault
VI
Sens. Gnd Fault
VI
Log Buffers
Configurable in Matrix
*
*
LED BI
On
Off
On
Off
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED
*
*
LED
On
*
LED
Off
on
m
LED
On
*
LED
Off
on
m
LED
On
*
LED
Off
on
m
LED
On
*
LED
Off
on
m
LED
On
*
LED
Off
On
Off
On
Off
A.9 Information List
IEC 60870-5-103
BO
151
6
1
Yes
151
18
4
No
151
19
4
No
BO
BO
BO
BO
BO
BO
BO
BO
151
101
1
Yes
BO
151
102
1
Yes
BO
151
103
1
Yes
BO
151
104
1
Yes
BO
151
107
1
Yes
BO
151
111
1
Yes
BO
151
112
1
Yes
BO
151
115
2
Yes
BO
151
117
2
Yes
BO
151
121
2
Yes
BO
151
123
2
Yes
BO
151
124
2
Yes
BO
151
126
2
Yes
BO
151
127
2
Yes
BO
151
129
2
Yes
BO
151
130
1
Yes
678

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siprotec sj63Siprotec sj64

Table of Contents