Addr.
Parameter
1617
67N POLARIZAT.
1618A
67N T DROP-OUT
1619A
ROTATION ANGLE
1630
M.of PU TD
1631
I/IEp Rf T/TEp
1701
COLDLOAD PICKUP
1702
Start Condition
1703
CB Open Time
1704
Active Time
1705
Stop Time
1801
50c-2 PICKUP
1802
50c-2 DELAY
1803
50c-1 PICKUP
1804
50c-1 DELAY
1805
51c PICKUP
1806
51c TIME DIAL
1807
51c TIME DIAL
1901
50Nc-2 PICKUP
1902
50Nc-2 DELAY
1903
50Nc-1 PICKUP
1904
50Nc-1 DELAY
1905
51Nc PICKUP
1906
51Nc T-DIAL
1907
51Nc T-DIAL
2001
67c-2 PICKUP
2002
67c-2 DELAY
2003
67c-1 PICKUP
2004
67c-1 DELAY
2005
67c-TOC PICKUP
2006
67c-TOC T-DIAL
2007
67c-TOC T-DIAL
2101
67Nc-2 PICKUP
2102
67Nc-2 DELAY
2103
67Nc-1 PICKUP
2104
67Nc-1 DELAY
2105
67Nc-TOC PICKUP
2106
67Nc-TOC T-DIAL
2107
67Nc-TOC T-DIAL
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
Function
C
67 Direct. O/C
with VN and IN
with V2 and I2
67 Direct. O/C
0.00 .. 60.00 sec
-180 .. 180 °
67 Direct. O/C
1.00 .. 20.00 I/Ip; ∞
67 Direct. O/C
0.01 .. 999.00 TD
0.05 .. 0.95 I/Ip; ∞
67 Direct. O/C
0.01 .. 999.00 TD
ColdLoadPickup
OFF
ON
ColdLoadPickup
No Current
Breaker Contact
79 ready
ColdLoadPickup
0 .. 21600 sec
ColdLoadPickup
1 .. 21600 sec
1 .. 600 sec; ∞
ColdLoadPickup
0.10 .. 35.00 A; ∞
ColdLoadPickup
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.10 .. 35.00 A; ∞
ColdLoadPickup
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.10 .. 4.00 A
5A
0.50 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
0.10 .. 35.00 A; ∞
ColdLoadPickup
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.10 .. 35.00 A; ∞
ColdLoadPickup
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.10 .. 4.00 A
5A
0.50 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
Setting Options
Default Setting
with VN and IN
0.00 sec
-45 °
OFF
No Current
3600 sec
3600 sec
600 sec
10.00 A
50.00 A
0.00 sec
2.00 A
10.00 A
0.30 sec
1.50 A
7.50 A
0.50 sec
5.00
7.00 A
35.00 A
0.00 sec
1.50 A
7.50 A
0.30 sec
1.00 A
5.00 A
0.50 sec
5.00
10.00 A
50.00 A
0.00 sec
2.00 A
10.00 A
0.30 sec
1.50 A
7.50 A
0.50 sec
5.00
7.00 A
35.00 A
0.00 sec
1.50 A
7.50 A
0.30 sec
1.00 A
5.00 A
0.50 sec
5.00
A.8 Settings
Comments
Ground Polarization
67N Drop-Out Time Delay
Rotation Angle of Reference
Voltage
Multiples of PU
Time-Dial
67N TOC
Cold-Load-Pickup Function
Start Condition
Circuit Breaker OPEN Time
Active Time
Stop Time
50c-2 Pickup
50c-2 Time Delay
50c-1 Pickup
50c-1 Time Delay
51c Pickup
51c Time dial
51c Time dial
50Nc-2 Pickup
50Nc-2 Time Delay
50Nc-1 Pickup
50Nc-1 Time Delay
51Nc Pickup
51Nc Time Dial
51Nc Time Dial
67c-2 Pickup
67c-2 Time Delay
67c-1 Pickup
67c-1 Time Delay
67c Pickup
67c Time Dial
67c Time Dial
67Nc-2 Pickup
67Nc-2 Time Delay
67Nc-1 Pickup
67Nc-1 Time Delay
67Nc-TOC Pickup
67Nc-TOC Time Dial
67Nc-TOC Time Dial
648