Siemens siprotec SJ62 User Manual page 653

Multi-functional protective relay with local control
Table of Contents

Advertisement

A Appendix
Addr.
Parameter
4008
46-TOC PICKUP
4009
46-TOC TIMEDIAL
4010
46-TOC TIMEDIAL
4011
46-TOC RESET
4012A
46 T DROP-OUT
4101
FCT 48/66
4102
STARTUP CURRENT
4103
STARTUP TIME
4104
LOCK ROTOR TIME
4201
FCT 49
4202
49 K-FACTOR
4203
TIME CONSTANT
49 Θ ALARM
4204
4205
I ALARM
4207A
Kτ-FACTOR
4208A
T EMERGENCY
4209
49 TEMP. RISE I
4210
49 TEMP. RISE I
4301
FCT 66
4302
IStart/IMOTnom
4303
T START MAX
4304
T Equal
4305
I MOTOR NOMINAL
4306
MAX.WARM STARTS
4307
#COLD-#WARM
4308
Kτ at STOP
4309
Kτ at RUNNING
4310
T MIN. INHIBIT
5001
FCT 59
5002
59-1 PICKUP
5003
59-1 PICKUP
5004
59-1 DELAY
5005
59-2 PICKUP
5006
59-2 PICKUP
5007
59-2 DELAY
5015
59-1 PICKUP V2
5016
59-2 PICKUP V2
5017A
59-1 DOUT RATIO
5018A
59-2 DOUT RATIO
5101
FCT 27
651
Function
C
46 Negative Seq
1A
0.10 .. 2.00 A
5A
0.50 .. 10.00 A
0.50 .. 15.00 ; ∞
46 Negative Seq
0.05 .. 3.20 sec; ∞
46 Negative Seq
46 Negative Seq
Instantaneous
Disk Emulation
46 Negative Seq
0.00 .. 60.00 sec
48/66 Motor
OFF
ON
48/66 Motor
1A
0.50 .. 16.00 A
5A
2.50 .. 80.00 A
48/66 Motor
1.0 .. 180.0 sec
0.5 .. 120.0 sec; ∞
48/66 Motor
49 Th.Overload
OFF
ON
Alarm Only
49 Th.Overload
0.10 .. 4.00
49 Th.Overload
1.0 .. 999.9 min
49 Th.Overload
50 .. 100 %
49 Th.Overload
1A
0.10 .. 4.00 A
5A
0.50 .. 20.00 A
49 Th.Overload
1.0 .. 10.0
49 Th.Overload
10 .. 15000 sec
40 .. 200 °C
49 Th.Overload
104 .. 392 °F
49 Th.Overload
48/66 Motor
OFF
ON
48/66 Motor
1.10 .. 10.00
48/66 Motor
3 .. 320 sec
48/66 Motor
0.0 .. 320.0 min
48/66 Motor
1A
0.20 .. 1.20 A
5A
1.00 .. 6.00 A
48/66 Motor
1 .. 4
48/66 Motor
1 .. 2
48/66 Motor
0.2 .. 100.0
48/66 Motor
0.2 .. 100.0
48/66 Motor
0.2 .. 120.0 min
27/59 O/U Volt.
OFF
ON
Alarm Only
27/59 O/U Volt.
40 .. 260 V
27/59 O/U Volt.
40 .. 150 V
0.00 .. 100.00 sec; ∞
27/59 O/U Volt.
27/59 O/U Volt.
40 .. 260 V
27/59 O/U Volt.
40 .. 150 V
0.00 .. 100.00 sec; ∞
27/59 O/U Volt.
27/59 O/U Volt.
2 .. 150 V
27/59 O/U Volt.
2 .. 150 V
27/59 O/U Volt.
0.90 .. 0.99
27/59 O/U Volt.
0.90 .. 0.99
27/59 O/U Volt.
OFF
ON
Alarm Only
Setting Options
Default Setting
0.90 A
4.50 A
5.00
0.50 sec
Instantaneous
0.00 sec
OFF
5.00 A
25.00 A
10.0 sec
2.0 sec
OFF
1.10
100.0 min
90 %
1.00 A
5.00 A
1.0
100 sec
100 °C
212 °F
OFF
4.90
10 sec
1.0 min
1.00 A
5.00 A
2
1
5.0
2.0
6.0 min
OFF
110 V
110 V
0.50 sec
120 V
120 V
0.50 sec
30 V
50 V
0.95
0.95
OFF
Comments
46-TOC Pickup
46-TOC Time Dial
46-TOC Time Dial
46-TOC Drop Out
46 Drop-Out Time Delay
48 / 66 Motor (Startup Moni-
tor/Counter)
Startup Current
Startup Time
Permissible Locked Rotor Time
49 Thermal overload protection
49 K-Factor
Time Constant
49 Thermal Alarm Stage
Current Overload Alarm Setpoint
Kt-FACTOR when motor stops
Emergency time
49 Temperature rise at rated sec.
curr.
49 Temperature rise at rated sec.
curr.
66 Startup Counter for Motors
I Start / I Motor nominal
Maximum Permissible Starting
Time
Temperature Equalizaton Time
Rated Motor Current
Maximum Number of Warm
Starts
Number of Cold Starts - Warm
Starts
Extension of Time Constant at
Stop
Extension of Time Constant at
Running
Minimum Restart Inhibit Time
59 Overvoltage Protection
59-1 Pickup
59-1 Pickup
59-1 Time Delay
59-2 Pickup
59-2 Pickup
59-2 Time Delay
59-1 Pickup V2
59-2 Pickup V2
59-1 Dropout Ratio
59-2 Dropout Ratio
27 Undervoltage Protection
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015