Siemens siprotec SJ62 User Manual page 682

Multi-functional protective relay with local control
Table of Contents

Advertisement

No.
Description
1580
>49 Reset of Thermal Overload
Image (>RES 49 Image)
1581
49 Thermal Overload Image reset
(49 Image res.)
1704
>BLOCK 50/51 (>BLK 50/51)
1714
>BLOCK 50N/51N (>BLK
50N/51N)
1721
>BLOCK 50-2 (>BLOCK 50-2)
1722
>BLOCK 50-1 (>BLOCK 50-1)
1723
>BLOCK 51 (>BLOCK 51)
1724
>BLOCK 50N-2 (>BLOCK 50N-2) 50/51 Overcur.
1725
>BLOCK 50N-1 (>BLOCK 50N-1) 50/51 Overcur.
1726
>BLOCK 51N (>BLOCK 51N)
1730
>BLOCK Cold-Load-Pickup
(>BLOCK CLP)
1731
>BLOCK Cold-Load-Pickup stop
timer (>BLK CLP stpTim)
1732
>ACTIVATE Cold-Load-Pickup
(>ACTIVATE CLP)
1751
50/51 O/C switched OFF (50/51
PH OFF)
1752
50/51 O/C is BLOCKED (50/51
PH BLK)
1753
50/51 O/C is ACTIVE (50/51 PH
ACT)
1756
50N/51N is OFF (50N/51N OFF) 50/51 Overcur.
1757
50N/51N is BLOCKED (50N/51N
BLK)
1758
50N/51N is ACTIVE (50N/51N
ACT)
1761
50(N)/51(N) O/C PICKUP
(50(N)/51(N) PU)
1762
50/51 Phase A picked up (50/51
Ph A PU)
1763
50/51 Phase B picked up (50/51
Ph B PU)
1764
50/51 Phase C picked up (50/51
Ph C PU)
1765
50N/51N picked up
(50N/51NPickedup)
1791
50(N)/51(N) TRIP
(50(N)/51(N)TRIP)
1800
50-2 picked up (50-2 picked up)
1804
50-2 Time Out (50-2 TimeOut)
1805
50-2 TRIP (50-2 TRIP)
1810
50-1 picked up (50-1 picked up)
1814
50-1 Time Out (50-1 TimeOut)
1815
50-1 TRIP (50-1 TRIP)
1820
51 picked up (51 picked up)
1824
51 Time Out (51 Time Out)
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
Function
Type
of In-
for-
matio
n
49 Th.Overload
SP
On
Off
49 Th.Overload
OUT
On
Off
50/51 Overcur.
SP
*
50/51 Overcur.
SP
*
50/51 Overcur.
SP
*
50/51 Overcur.
SP
*
50/51 Overcur.
SP
*
SP
*
SP
*
50/51 Overcur.
SP
*
ColdLoadPickup
SP
*
ColdLoadPickup
SP
On
Off
ColdLoadPickup
SP
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
OUT
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
On
Off
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
50/51 Overcur.
OUT
*
Log Buffers
Configurable in Matrix
*
*
LED BI
*
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED
On
*
LED
Off
*
*
LED
*
*
LED
On
*
LED
Off
*
*
LED
On
m
LED
Off
On
m
LED
Off
On
m
LED
Off
On
m
LED
Off
On
m
LED
Off
on
m
LED
On
*
LED
Off
*
*
LED
on
m
LED
On
*
LED
Off
*
*
LED
on
m
LED
On
*
LED
Off
*
*
LED
A.9 Information List
IEC 60870-5-103
BO
BO
BO
BO
BO
60
1
1
Yes
BO
60
2
1
Yes
BO
60
3
1
Yes
BO
60
4
1
Yes
BO
60
5
1
Yes
BO
60
6
1
Yes
BO
BO
60
243
1
Yes
BO
BO
60
21
1
Yes
BO
60
22
1
Yes
BO
60
23
1
Yes
BO
60
26
1
Yes
BO
60
27
1
Yes
BO
60
28
1
Yes
BO
160
84
2
Yes
BO
160
64
2
Yes
BO
160
65
2
Yes
BO
160
66
2
Yes
BO
160
67
2
Yes
BO
160
68
2
No
BO
60
75
2
Yes
BO
60
49
2
Yes
BO
160
91
2
No
BO
60
76
2
Yes
BO
60
53
2
Yes
BO
160
90
2
No
BO
60
77
2
Yes
BO
60
57
2
Yes
680

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siprotec sj63Siprotec sj64