Dual Or Sequenced Gates: Power, Software & Accessory Requirements; Programming A Dual Gate (Interlocked Pair) - HySecurity SlideDriver 15 Programming & Operation Manual

Smart touch controller
Hide thumbs Also See for SlideDriver 15:
Table of Contents

Advertisement

Dual or Sequenced Gates: Power, Software &
Accessory Requirements
When installing an interlocked pair, the following must be adhered to:
An electrical conduit for interconnecting wires must span between the two operators. The interlock
(dual gate) communication wires and any low voltage control wires must be installed in a conduit that is
separate from the high voltage power cables.
Complete the installation of both operators as separate machines and verify that their basic functions are
correct as solo operators before interconnecting them.
Be sure both operators are running the same software. The software version can be viewed on the display
by pressing the RESET button.
Keep the most current software loaded. It is available at http://www.hysecurity.com. Make it part of your
maintenance routine to check for and install software updates on a regular basis.
External control inputs (vehicle detectors and entrapment protection sensors) may be connected to
either gate operator in a Primary/Secondary configuration, but in a Sally Port configuration, the external
control inputs must be connected to Sally Port A. (Sally Port A being the first gate to open for incoming
traffic. Be sure to designate Sally Port A in the dual gate menu item as 3 (DG 3) and Sally Port B as
4 (DG 4).

Programming a Dual Gate (Interlocked Pair)

Both gate operators must be programmed so they know what function they are to perform as Primary and
Secondary or Sally Port A and Sally Port B. (Sally Port A being the first
gate to open for incoming traffic.) The Installer Menu provides the Dual
Gate (DG) menu item that sets up the functionality of the gate operators.
Access this menu item by taking the following steps:
Press Menu twice at
Status Display
the gate status display.
User Menu
CT 0 or HC 1
To access the Installer Menu,
press and hold Reset & Open,
and then release them.
Refer to the table below to set the operator's functionality.**
**Interlocked Gate type
Sally Port
Primary / Secondary
www.hysecurity.com
Installer Menu
FD 0
Press Next until DG
characters appear.
Operator 1 (Primary)
1. Press Next until DG 3 appears on the display.
2. Press Select to establish the operator as
Sally Port A.
1. Press Next until DG 2 appears on the display.
2. Press Select to establish the operator as
Primary.
Dual Gate Systems
Dual Gate
DG 0
Press Select so DG
characters blink.
Press Next to change
the display. Refer to
chart below.
1. Press Next until DG 4 appears on the display.
2. Press Select to establish the operator as
Sally Port B.
1. Press Next until DG 1 appears on the display.
2. Press Select to establish the operator as
Secondary.
DG 0
DUAL GATE
Operator 2 (Secondary)
D0559 Rev. A
67