Configuration Examples

The following describes examples of configuration required to use software-link features or for
system operations.

Link with Management Software

To link with the temperature monitoring feature of ESMPRO
Select [Server] - [Thermal Sensor] - [Enabled].
To control the power supply of the server with ESMPRO Manager via the network
To control via NIC
!
Select [Advanced] - [Advanced Chipset Control] - [Wake On LAN] - [Enabled].
Select [Server] - [AC-LINK] - [Stay Off].

UPS

To link power supply with the UPS
To power on the server when power is supply from the UPS
!
Select [Server] - [AC-LINK] - [Power On].
To keep the server off-powered even when power is supplied from the UPS if the POWER
!
switch was used to power off
Select [Server] - [AC-LINK] - [Last State].
To keep the server off-powered even when power is supplied from the UPS
!
Select [Server] - [AC-LINK] - [Stay Off].

Boot

To change the boot order of devices connected to the server
Select [Boot] and specify the boot order.
To display POST check results
Select [Advanced] - [Boot-time Diagnostic Screen] - [Enabled].
You can also press Esc while the OEM logo is on the screen to display POST check
results.
To control from the HW console
Select [Server] - [Console Redirection] and set each item.