Disk Array Configuration of Built-in Hard Disks
For the disk array configuration of hard disks installed in the built-in 3.5-inch device bay, an
optional disk array controller board is installed in the server. The SCSI cable connected to the
Ultra320 (A) connector is disconnected from the connector on the system board and then connected
to the disk array controller board instead. The server can be equipped with up to four disk array
controller boards.
Some disk array controllers contain more than one channel. In that case, connect one of the two
channels to the SCSI backplane connector of the 3.5-in device bay and the remaining channel to an
additional disk cabinet.
Mother board
Disk array controller board
PCI#1
PCI#2
PCI#3
PCI#4
PCI#5
PCI#6
Ultra SCSI (B)
Ultra SCSI (A)
SCSI cable
HSBP cable
Terminator
Option
Option
FDD
IDE
HSBP (B)
HSBP (A)
IDE cable
Floppy disk drive cable
Internal Cabling Diagrams 8-3
5.25-inch
device bay
CD-ROM
Floppy disk
drive
ID0
3.5-inch
ID1
device bay
ID2
Hard disks
ID3
are optional.
ID4