Make sure that the heat sink is level.
10.
NOTES:
If the heat sink is not level, remove it, and then install it again. The
!
following probably causes the heat sink not to be level:
– The heat sink is not positioned correctly.
– The wire clip is not engaged correctly.
Do not move the secured heat sink.
!
Install the components you removed previously.
11.
Power on the server, start the SETUP utility, and set "Processor Retest" of "Processor
12.
Settings" on the Main menu to "Enabled".
Insert the EXPRESSBUILDER CD into the CD-ROM drive, and start the system booting
13.
from the EXPRESSBUILDER CD.
See the EXPRESSBUILDER User's Guide, located on the EXPRESSBUILDER
CD-ROM, for details.
Diagnose the system.
14.
See the EXPRESSBUILDER User's Guide, located on the EXPRESSBUILDER
CD-ROM, for details.
Verify the temperature indication (Crnt column) displayed on the diagnostic window.
15.
Upgrading your Server 7-39