FUNCTIONS
(3) Startup program
Basic
Universal
UD
Note6.36
Note6.36
Redundant
Universal
UD
Note6.37 Note6.37
Note37
Basic
Universal
In the case of Basic model QCPU, a program cannot be started from the program list monitor
UD
screen.
Note6.36 Note6.36
Note38
Redundant
Universal
Since the Redundant CPU and Universal model QCPU cannot use low speed execution type
UD
programs, "Low speed execution" cannot be selected in the start mode.
Note6.37 Note6.37
Note6.36
Program can be started on the program list monitor screen.
Clicking the
Startup program
(a)
(b)
(a) Program name
Select the program set in the program setting of the PLC parameter dialog box.
A program name cannot be entered as desired.
(b) Startup mode
The stand-by type program can be changed to "Scan execution", "Low speed
Note6.37
execution"
or "Fixed scan execution".
The value set in the program setting of the PLC parameter dialog box is displayed
as the default value of fixed scan execution. ms or scan be selected as the
unit.Note38
Note37
button displays the following dialog box.
Figure 6.62 Startup program screen
6.13 Execution Time Measurement
6.13.1 Program list monitor
1
2
3
4
5
6
7
8
6
- 95