SC Tables: SC5xx (Paper Feed and Fusing)
SC No.
Level
SC561-00
A
SC No.
Level
SC562-02
A
SC562-05
D
D197/D198/D199/D200/D201/D202
Error Name/Error Condition/Major Cause/Solution
Pressurized Central Thermistor Disconnection
When the pressurized central thermistor detects a
predetermined temperature or less for specified seconds
consecutively.
Detection period 100ms, detection count: 10 times or more.
Thermistor disconnection
Connector disconnected
Replace the thermistor.
Reset the connector.
Replace the connector.
Replace the fusing unit.
Error Name/Error Condition/Major Cause/Solution
Pressurized Central Thermistor Does Not Reload
Pressurized Central Thermistor Does Not Reload (Low Voltage)
When the pressurized central thermistor does not reach a
predetermined temperature for specified seconds consecutively.
Thermistor dirt
Thermistor deformation, float
Outside input voltage guarantee
After excess temperature rise prevention unit operation
Replace the thermistor.
Make sure that the input voltage is within acceptable limits.
Replace the fusing unit.
6-64