5.
Connect the ICIB-3 with bracket 1 [A] to CN 505 on the IPU (
6.
Reassemble the machine.

User Tool Setting

1.
Plug in and turn on the main power switch.
2.
Go into the User Tools mode, and select System Settings > Administrator Tools > Data
Security for Copying > "On".
3.
Exit the User Tools.
4.
Check the operation.
The machine will issue an SC165 error if the machine is powered on with the
ICIB-1 removed and the "Data Security for Copying" feature is set to "ON".
When you remove this option from the machine, first set the setting to "OFF" with
the user tool before removing this board. If you forget to do this, "Data Security for
Copying" feature cannot appear in the user tool settings. And then SC165 will
appear every time the machine is switched on, and the machine cannot be used.
SM
Copy Data Security Unit (B829)
x 2; M3 x 6).
2-81
D129/D130